Description

2.1

Product overview

Facepiece (see Figure Z1 on page 226)
Connector type (see Figure Z2 on page 226)
1
Visor frame, top
3
Adjuster buckle
5
Facepiece body
7
Cap
9
Nose cup valve
11 Visor
13 Button
15 Exhalation valve seat
17 Spring holder
19 Inhalation valve disc
and valve seat
21 O-Ring
2.2

Feature description

Dräger FPS 7000 facepieces are available with the following
connectors:
round thread connection RD40x1/7" according to EN 148-1
RA
for canisters
plug
connection
(Dräger-specific)
P
breathing apparatus or air line breathing apparatus
Dräger FPS 7000
2
Head harness
4
Neck strap
6
Exhalation valve cover
8
Visor frame, bottom
10 Nose cup
12 Connector
14 Speech diaphragm
16 Exhalation valve spring
18 Exhalation valve disc
20 Clamping ring
for
self-contained
(text approved by NIOSH, not approved by any other notified body)
Special facepiece spectacles are available for users who wear
spectacles.
Instead of the harness a special hairnet can be used.
The facepieces can be used within a temperature range between
-22 °F to 140 °F (-30 °C to +60 °C). Lower or higher temperatures are
permitted when the exposure time is short.
2.3

Intended use

The facepieces of the Dräger FPS 7000 series protect the face and the
eyes against aggressive media. They must only be used with NIOSH-
approved self-contained breathing apparatus, air line breathing
apparatus, or canisters.
2.4

Approvals

The facepieces in combination with self-contained breathing
apparatus, air line breathing apparatus, or canister comply with the
US NIOSH directives 42 CFR 84, subpart H. Only combinations that
are approved by NIOSH may be used in the USA (see "Approval
Label" on page 225).
Furthermore, the facepieces are approved according to EN 136:1998
CL.3+ and are marked with the CE mark of conformity. In addition, they
meet the flame engulfment requirements stipulated in EN 137.
The Dräger FPS 7000 RA facepieces are also approved in Australia
and New Zealand according to AS/NZS 1716:2012.