TOOL HOLDER ASSEMBLY
(Not standard with all models)
1. Replace tank cover and apply pressure with thumbs to each latch until it
snaps tightly in place. Make sure both lid latches are clamped securely.
2. With rear of unit facing you, take tool holder and position it with the tabs
facing rear tank cover (Figure 6).
3. Press tabs of tool holder into the slots on mounting lugs on rear of tank
cover (Figure 7).
4. Press down until tabs snap into place.
WARNING
– ALWAYS DISCONNECT THE PLUG FROM THE
WALL OUTLET BEFORE REMOVING THE TANk COVER.
DRY PICk UP
INSTALLING FOAM SLEEVE AND REUSABLE
DRY FILTER
(Not standard with all models)
WARNING
– ALWAYS DISCONNECT THE PLUG FROM THE
WALL OUTLET BEFORE REMOVING THE TANk COVER.
When using the reusable dry filter to pick up dust and dry material, you must
install foam sleeve and reusable dry filter to ensure proper filtration. Make
sure inlet deflector is fully inserted into deflector guide on inside of tank. If
it is not, install inlet deflector by sliding it downward into slot on deflector
guide (Figure 8). NOTE: Hose must be removed before inlet deflector can be
inserted into or removed from deflector guide. Opening on
inlet deflector can face either side of tank. Inlet deflector
should always be in place for any type of cleaning. If the
vacuum has been used to pick up liquids, the foam sleeve
must be cleaned and dried before installing for dry pick
up. With tank cover in an upside down position, slide
foam sleeve down over lid cage pulling until foam sleeve
completely covers lid cage (Figure 9). NOTE: Bottom of
foam sleeve must be positioned on the OUTSIDE of groove
around lid cage for the reusable dry filter to fit properly
(Figure 10, 11). Center the reusable dry filter on lid cage
(Figure 12), slide mounting ring down over filter until
ring is positioned against the ribs of the lid cage (Figure
13). The reusable dry filter should always be in position
over the foam sleeve for dry pick up. To remove the filter
for cleaning, remove mounting ring and filter from lid
cage (Figure 14). To clean the reusable dry filter, shake off excess dirt and dust or (depending
on the condition of the filter) rinse with water. Allow the filter to dry completely and reinstall.
DO NOT MACHINE WASH OR DRY.
INSTALLING THE CARTRIDGE FILTER
(Not standard with all models)
NOTE: IF FOAM SLEEVE IS IN POSITION OVER LID CAGE, IT DOES NOT NEED TO BE REMOVED
BEFORE INSTALLING CARTRIDGE FILTER. FOAM SLEEVE MUST BE POSITIONED ON THE INSIDE
OF THE GROOVE LOCATED AROUND LID CAGE FOR CARTRIDGE FILTER TO FIT PROPERLY.
The cartridge filter can be used for wet or dry pick up; installation is the
same for both. When picking up large quantities of liquid please refer to the
Wet Pick Up Operation section in the manual. Use the cartridge filter in posi-
tion over the lid cage for most general dry pick up. Make sure inlet deflector
is fully inserted into deflector guide on inside of tank. If it is not, install inlet
deflector by sliding it downward into slot on deflector guide (Figure 15).
NOTE: Hose must be removed before inlet deflector can be
inserted into or removed from deflector guide. Opening on
inlet deflector can face either side of tank. Inlet deflector
should always be in place for any type of cleaning. With the
tank cover in an upside down position, slide the cartridge
filter down over the lid cage, pushing until the filter seals
against the cover (Figure 16). Place filter retainer into
the top of the cartridge filter, hold the tank cover with one
hand, turn the handle on the filter retainer clockwise to
tighten, locking the filter into place (Figure 17 & 18). To
remove filter for cleaning, hold the tank cover and turn
the filter retainer counter-clockwise to loosen and remove,
slide the cartridge filter off the lid cage (Figure 19 & 20).
To clean filter shake or brush off excess dirt or rinse (from
the inside of the filter) with water, dry completely (approxi-
mately 24 hours) and reinstall (Figure 21 & 22). NOTE: If
the filter has been used for wet pick up, it must be cleaned
and dried before using for dry pick up.
CAUTION
– kEEP FILTERS CLEAN.
EFFICIENCY OF ThE VACUUM IS LARGELY DEPENDENT ON ThE FILTER. A CLOGGED FILTER
6
7
8
9
10
12
11
13
14
15
16
17
18
19
20
21
22
CAN CAUSE OVERhEATING AND POSSIBLY DAMAGE ThE CLEANER. ChECK ThE FILTER PERI-
ODICALLY AND REPLACE AS REqUIRED.
INSTALLING THE DISPOSABLE FILTER BAG
(Not standard with all models)
1. Use for dry pick up only. Use in conjunction with cartridge filter for picking up soot, cement,
plaster or drywall dust.
2. With cord disconnected from receptacle, pull latches in an outward motion and remove
tank cover.
3. Unscrew hose locking-nut and remove hose from inlet (Figure 23).
4. Remove inlet deflector from deflector guide (Figure 24). NOTE: Hose must be removed
before inlet deflector can be taken out.
5. With the opening of the inlet deflector facing the left or right side of the filter bag, slide
filter bag collar over deflector matching notches of bag collar to tabs on inlet deflector, bag
will only fit properly one way (Figure 25).
6. Slide deflector with collection bag attached into deflector guide (Figure 26).
7. Reinsert hose into inlet and tighten locking-nut (Figure 27).
8. When secured in place, expand bag and position around the inside of tank.
9. Replace tank cover.
NOTE: When removing filter bag from tank, remove inlet deflector from filter bag collar and
reinstall into deflector guide. Inlet deflector should always be in place for any type of cleaning.
24
23
26
WARNING FOR FINE DUST & POWDERS
When vacuuming fine dust, or powders of any kind (ex. plaster, drywall dust, cold ashes, con-
crete dust, etc.)...a high efficiency drywall filter bag must be used. When vacuuming nor-
mal household dust and debris, standard household disposable filter bags may be used. These
"large bag" filters connect to the air inlet fitting on the inside of the vacuum tank.
FILTER SELECTION GUIDE
Fine dust
SIZE
Drywall
5-8 U.S. Gal (18.9-30.3L)
90671/
H
10-14 U.S. Gal (37.8-53L)
90672/
I
15-22 U.S. Gal (56.8-83.2L)
90673/
J
WET PICK UP OPERATION
Remove ALL dirt and debris found in the tank. The vacuum requires only
a minimum of conversion when going from dry to wet pick up. Remove
all dry use filters from the vacuum. A clean cartridge filter may be used
for vacuuming small amounts of liquids. For best results when vacuuming
large quantities of liquid, remove the cartridge filter. When vacuuming
liquids containing debris, it is recommended purchasing a foam sleeve and
installing over filter cage; otherwise a foam sleeve is not required for wet
pick up. Foam sleeve and additional filters may be purchased by visiting our
website at www.shopvac.com, contacting our customer service department,
®
or purchasing at your local Shop-Vac
deflector guide on inside of tank. If it is not, install inlet deflector by sliding it downward into
slot on deflector guide (Figure 28). NOTE: Hose must be removed before inlet deflector can be
inserted into or removed from deflector guide. Opening on inlet deflector can face either side
of tank. Inlet deflector should always be in place for any type of cleaning.
may occur if the filter becomes saturated during wet pick up. If misting occurs, remove filter and
allow to dry or, replace with another dry filter to eliminate the misting and possible dripping of liquid
around the lid. Turn the unit off immediately upon completing a wet pick up job or when tank is full
and ready to be emptied. Raise the hose to drain any excess liquid into the tank. The interior of the
tank should be periodically cleaned.
The foam sleeve should be cleaned periodically as described in the following steps:
1. Always disconnect the plug from the wall receptacle before removing the tank cover. Place tank
cover in an upside down position. Remove foam sleeve by sliding it up and off the lid cage.
2. Shake excess dust off foam sleeve with a rapid up and down movement.
3. Hold foam sleeve under running water for a minute or two, rinsing from the inside. A water wash
is not always required, depending on the condition of the foam sleeve.
4. Gently wring out excess water, blot foam sleeve with a clean towel, and allow to dry. The foam
sleeve is now ready to be reinstalled on the lid cage.
NOTE: WET PICK UP ACCESSORIES SHOULD BE WASHED PERIODICALLy, ESPECIALLy AFTER
PICKING UP WET, STICKy KITCHEN ACCIDENTS. THIS CAN BE ACCOmPLISHED WITH A WARm
SOLUTION OF SOAP AND WATER.
25
27
90107/
REUSABLE DRY FILTER AND MOUNTING RING
S
Standard
fits most Shop-Vac
Wet/Dry Vacuums.
®
Household
90661/
E
90585/
R
FOAM FILTER SLEEVE fits most Shop-Vac
F
90662/
Wet/Dry Vacuums and should remain in place
90663/
G
at all times.
28
Make sure inlet deflector is fully inserted into
distributor.
Misting in exhaust air
®