5.1 Cleaning the fi lter
The vibration function (switch setting R or RA /switch ②a) should
be activated at the latest when the volume fl ow display ②c (warn-
ing lamp) lights up or when the warning signal sounds or when the
suction output sinks.
5.2 Automatic cleaning
Filter cleaning is performed (switch setting RA/switch ②a) auto-
matically during the next working break when the minimum volume
fl ow level is reached.
6 Emptying the container
Only permitted for dust with AGW's > 1mg/m
Switch the vacuum cleaner off, pull the mains plug out.
▷ Open the latches.
▷ Remove the cover and suction hose from the container.
▷ Empty the container by pouring out.
6.1 Dispose of the fl eece fi lter bag
▷ Pull the mains plug
out.
▷ Fit mouth protection.
▷ Remove suction hose, close off the suction spigot with a plug*.
▷ Open the side latches, remove the top section.
▷ Carefully pull the fl ange off the suction spigot and close off the
fl ange.
▷ Dispose of the vacuumed up material in accordance with legal
requirements.
▷ Mount a new fl eece fi lter bag
6.2 Dispose of the PE emptying and disposal bag
▷ PE emptying and disposal bag: Switch the vacuum cleaner on,
shake the folding fi lter cassettes. Switch off the vacuum cleaner.
▷ Fit mouth protection.
▷ Remove suction hose, close off the suction spigot with a plug*.
▷ Open the side latches, remove the top section.
Before setting aside the top section, switch to >I< position, to
draw up any fl oating dust which may exist.
▷ Close off the PE emptying and disposal bag carefully with the
tape provided.
▷ Carefully pull the fl ange off the suction spigot and close it off
▷ Remove the PE emptying and disposal bag carefully from the
container
▷ Dispose of the vacuumed up material in accordance with legal
requirements.
▷ Mount a new PE bag
(see chapter 6.4)
6.3 Insert fl eece fi lter bag
Only use fl eece fi lter bags for dry vacuum cleaning.
▷ Slide the fl ange completely over the suction aperture.
26 - en
NOTE
3
(see chapter 6.3)
NOTE
Operating the rotary slider*
▶ Push the rotary slider* from the inside to the outside, turn
through 180° (see mark) and then push inwards again from
the outside through the suction spigot
▶ Place the rotary slider* in the suction aperture with the mark
▲ pointing upwards.
(* depending on the equipment variant)
▷ Place the upper section on the container and close the side
latches.
6.4 Insert PE emptying and disposal bag*
Only the vacuum cleaners class M and H with special containers
and rotary slider in the suction aperture of types RP250YDM
and RP500YDM are suitable for the use of PE Emptying and
disposal bags.
Operating the rotary slider*
▶ Push the rotary slider* from the inside to the outside, turn
through 180° (see mark) and then push inwards again from
the outside through the suction spigot
▶ Place the rotary slider* in the suction aperture with the mark ●
pointing upwards.
▷ Slide the fl ange completely over the suction aperture and place
the upper bag opening over the edge of the container.
▷ Place the upper section on the container and close the side
latches.
(* depending on the equipment variant)
NOTE
NOTE
NOTE