Testing Individual Wireless Keys
Do not use the individual device test described above to test wireless keys. To ensure that the TR5164 is
receiving transmissions from these devices, use the function keys on the wireless keys at several
different points throughout the installation.
NOTE: Two-way wireless keys must be activated by pressing any key before they become
functional.

5.2 Mounting

Once reception between the TR5164 and all wireless devices has been tested and verified (Section 5.1,
page 11), mount as follows:
TR5164
1. Pull the Keybus wires through the holes at the back of the cabinet or through the breakaway tabs at
the sides.
2. Mount the cabinet securely to the wall using the supplied 2 (two) screws. See Figure 2.
Breakaway
Breakaway
Tab
Tab
Figure 2
Wireless Devices
Mount the wireless devices once the placement test described in section 5.1 has been successfully
completed and three "good" results in a row have been achieved for each device. See the installation
sheet for each device for mounting instructions.
Now that the TR5164 and wireless devices are mounted and working properly, read Section 6.1, page
13, for information on potential wireless trouble conditions and battery replacement.