4. CHECK BEFORE OPERATION

4.1 Engine Oil Level
NOTE: Always check the engine oil level when
the engine is standing on a flat surface and is
not running.
4.1.1 Remove the oil filler cap and use a clean
cloth to clean the oil dipstick.
4.1.2 Insert the dipstick into the oil filler neck
without turning.
4.1.3 When the oil level is below the lower limit
on the oil dipstick, use the recommended oil to
refill up to the upper limit.
4.1.4 Replace the oil filler cap.

4.2 FUEL LEVEL

4.2.1 Remove the fuel tank cap.
4.2.2 Fill the fuel tank up to the filter collar.
4.2.3 Recheck the fuel level and refill, if
necessary.
4.2.4 Fasten the fuel tank cap until it is secured.
4.3 AIR FILTE
4.3.1 Detach the clip, and remove the air filter
housing.
4.3.2 Check the filter to make sure that it is clean
and in good condition. When it is damaged, use
a new one as a replacement. (B3)
4.3.3 When the filter element is dirty, clean it by
going through the following steps. (B4)
a) Wash the filter element using a cleaning
agent.
b) Let the element dry.
c) Soak the element in clean engine oil.
d) Squeeze out excessive oil.
38
4.3.4 Reinsert the filter element, attach the air
filter cover and tighten it. (B5)
4.4 BATTERY (B6)
Check and make sure that the electrolyte of
each battery is between the UPPER and LOWER
markings.
1 UPPER marking
2 LOWER marking

5. STARTING THE GENERATOR

5.1 Remove all loads from AC outlet.
5.2.1 Set the AC breaker to "ON". (B7)
5.2.2 Electrical direct current connector (DC)
This function is provided to charge 12V batteries
(external).
Charge batteries only when they are taken out.
- Check, if the 12V overload protection is pressed
(DC Reset)
- Make sure the generator is not in operation,
and connect the battery.
- Pay attention to the polarity of the cable (RED=
+(plus), BLACK = -(minus)), and the polarity of
the battery.
- Make sure to read the notes on charging of the
battery manufacturer!
After the generator is connected (connection
of battery and insertion of charging plug into
12V outlet of generator), it can be started and
the battery can be charged. When the charging
process is completed, first switch off the
generator, and then disconnect the battery.
Pay attention to sufficient ventilation, because
flammable gasses are generated while charging
the battery, and keep away from ignition sources
(smoking, fire, open light,...). Wear acid-proof
gloves and safety goggles to protect yourself
against accumulator acid which might leak out.