1.1. Safety Symbols
The following symbols are imprinted on the front panel of the meter to
remind you of measurement limitations and safety.
10 A
mA
WARNING
CAT III
The maximum current that you can measure at
this terminal is 10 A DC/AC. This terminal is fuse
protected by F 10A/600 V fuse. When using this
range with high current, keep the duty cycle to 30
sec. on load and 15 minutes off load.
The maximum current that you can measure with
this terminal is 200 mA that is fuse protected by
200 mA/600 V fuse.
Refer to the complete operating instructions.
To avoid electrical shock or instrument damage,
do not connect the common Input COM Terminal
to any source of 600 V DC/AC with respect to
earth ground.
The maximum voltage this meter can measure is
600 V DC/AC
This WARNING symbol indicates potentially
hazardous situation, which if not avoided, could
result in death or serious injury.
Be exceptionally careful when measuring high
voltages. Do not touch the terminals or test leads
ends
Indicates protection class II
(Double Insulation)
Overvoltage category III