4. Make sure the in-take sponge filter is cleaned after
each use.
5. Pump clean/ fresh water for one minute through the
water pump and the blade guard to prevent waste
build-up and clogging.
Do not run the pump without water.
Front plate
accessory
Impeller
Sponge
FIGURE 25
DIAMOND BLADES
1. Use only 10 in. wet continuous rim diamond blade
with this saw.
2. Arbor size is 5/8 in.—please choose the right size to
fit the inner flange.
3. Do not use wood sawing blade, or other blades not
suitable for ceramic, porcelain or stone—severe
body injury or the saw damage may occur.
4. This saw comes with a standard blade that is ideal
for cutting ceramic tile. If your project requires the
cutting of other substrates (ex. porcelain, slate,
stone), it is recommended that you use the specific
type of blade for the material being cut.
THE FOLLOWING ARE DIAMOND BLADE SAFETY
PRECAUTIONS:
• ALWAyS INSpECT BLADES for cracks or uneven wear.
Discard cracked, chipped or bent blades!
• ALWAYS USE MANUFACTURER'S RECOMMENDATION
for matching the right blade with the right material
being cut.
• INSPECT THE ARBOR SHAFT for uneven wear before
mounting the blade.
• ALWAYS USE BLADES WITH THE CORRECT ARBOR
SIzE on a compatible arbor shaft.
• ENSURE THE BLADE IS MOUNTED WITH THE
ROTATION ARROW IN THE PROPER DIRECTION and is
securely tightened with a wrench.
Impeller
Pump
lid
shaft
• ALWAYS WEAR PROPER SAFETY EqUIPMENT at all
times when operating the saw. Wear goggles and
dust mask at all times when operating saw.
• ALWAYS ENSURE A CONTINUOUS FLOW OF WATER on
both sides of the blade before cutting any material.
• Do NoT opERATE THE SAW WITHoUT ALL SAFETy
GUARDS IN POSITION.
• Do NoT opERATE THE SAW WITH BLADES LARGER
OR SMALLER THAN RECOMMENDED.
• Do NoT CUT DRy WITH BLADES MARKED "USE WET."
• DO NOT ExCEED MAxIMUM RPMS recommended by
the blade manufacturer.
• DO NOT FORCE THE MATERIAL into the blade. Let the
blade cut at its own speed.
• Do NoT CUT MATERIAL NoT RECoMMENDED By THE
BLADE MANUFACTURER.
TROUBLESHOOTING
IF THE SAW IS OVERHEATING:
• Turn saw off and let it rest until motor is cool to the
touch.
• Check and clean the ventilation slots, removing
blockage and dirt.
IF THE SAW DOES NOT START:
• Check that the power switch is in the "oN" position.
• Check that the power cord is plugged in properly.
• Confirm that the power source voltage is 120V from
outlet.
IF WATER IS NOT FLOWING THROUGH THE
WATER PUMP:
• Make sure water in tray is high enough to clear the
intake nozzle.
• Make certain the water valve connecting the pump to
the tubing is in the "ON" position.
• Check water hose for connection or clogs.
• Check that the power cord is plugged in properly.
• Check for excess debris on intake filter.
IF THE CUTTING TABLE IS NOT SLIDING SMOOTHLY:
• Thoroughly clean guide rails.
If problem continues, call our Customer Service
Department at 1-866-435-8665.