Using the refrigerator
7.14
Operating with low ambient temperatures
A
NOTICE!
Do not attach the top winter covers (not in scope of delivery) while
operating with gas. This prevents heat from building up and the fumes
from the refrigerator can be extracted properly.
I
NOTE
• Cold air can restrict the performance of the unit. Attach the winter
covers if you experience a reduced cooling capacity at low ambient
temperatures. This protects the unit from excessively cold air that
might otherwise restrict its performance.
• Attach the winter covers when the vehicle is cleaned from the out-
side or not used for a prolonged period of time.
Attach the winter covers to both ventilation grilles. To do this, proceed as follows:
• LS330 ventilation grille: fig. f, page 7
• LS230 ventilation grille: fig. g, page 8
I
NOTE
You recognise a mounted winter cover on the LS230 ventilation grille by
the bolts protruding from the ventilation grille (fig. g 1, page 8).
7.15
Replacing the batteries in the igniter (RML9430 only)
Proceed as follows (fig. h, page 9):
➤ Using a screwdriver, press the cap on the battery igniter in 2 or 3 mm and turn it
90° to the left (A).
➤ Remove the cap (B).
➤ Remove the battery (B).
➤ Insert the new battery (type AA). Make sure the polarity is correct.
➤ Put the cap back on.