INSTALLATION
TROUbLESHOOTING
1
2
a a a
Drill holes at all four markings. Secure the wall mounting bracket
»
with suitable materials (screws, rawl plugs) depending on the
type of wall. With the vertical slots, you can compensate for an
offset fixing hole.
10.2 appliance installation
Hook the appliance by its slots in the back of the appliance on
»
to all four tabs of the wall mounting bracket simultaneously.
Push the appliance to latch it in position.
»
Turn the locking bolt in the wall mounting bracket fully clockwise;
»
this locks the appliance in place.
Push the safety cap onto the locking bolt to prevent it from
»
loosening.
1 Locking bolt
2 Wall mounting bracket
1
1 Appliance
6
|CNS E
2 Safety cap
3
3 Locking bolt
10.3 Dismounting the appliance
4
»
1 Appliance
2 Safety cap
3 Locking bolt
»
»
10.4 power supply
»
»
1
2
11. troubleshooting
The power cable must only be replaced by a contractor using our
2
original spare parts.
12. appliance handover
3
Explain the functions of the appliance to the user. Draw special
attention to the safety information. Hand the operating and
installation instructions to the user.
remove the safety cap from the locking bolt.
1
undo the locking bolt on the wall mounting bracket.
Lift the appliance up slightly and pull it forwards and away from
the wall mounting bracket.
Ensure the on-site supply cable has an adequate cross-section.
Ensure a socket or junction box for a permanent power supply
is installed at a distance of at least 4˝ / 10 cm from the side of
the appliance.
DanGEr Electrocution!
carry out all electrical connection and installation
work in accordance with all national, state and local
building code.
DanGEr Electrocution!
Each heater must be wired directly to the circuit
breaker panel with the proper size breaker and wire
gauge.
DanGEr Electrocution!
Do not plug the heater into a wall outlet.
the specified voltage on the nameplate must match
the voltage at the circuit breaker panel.
WWW.STIEbEL-ELTRON-USA.COM