PLANET
11 - MAINTENANCE
All maintenance and cleaning
operations must ALWAYS be carried
out when the vacuum is off and disconnected
from the electricity main.
The suction unit needs no particular maintenance,
cleaning or lubrication.
Remember however that correct use and servicing
are essential if the safety and effi ciency of the
vacuum are to be guaranteed.
To ensure regular and constant operations and
to prevent the warranty from becoming void,
use always original spare parts when repairs
are needed.
11.1 Routine maintenance
11.1.1 Before each daily start and
shutdown
- Check that the power cable has not been
damaged, torn or crushed
- Check the integrity and functionality of the
electrical switches
- Check the state of the art of the main
tank fi lling (and of the fi lling head when
present)
IMPORTANT
If the vacuum cleaner purchased is ATEX, empty
the main drum.
- Check the condition of the suction hose
- Check that the suction head is correctly
positioned on the main tank
- Make sure that the power voltage of the
electrical mains correspond to the one on the
technical data plate
- If the vacuum cleaner is moved, please
make sure that the voltage on the socket
is the same as the voltage indicated on
technical data label of the machine.
11.1.2 Every 200 hours working
- Verify the condition of the primary fi lter
for tears holes or other damages; in case
change the fi lter (§11.2)
- Check the integrity and readability of
the technical data plate: replace it if it's
damaged or incomplete
IMPORTANT
PERFORM THE FOLLOWING OPERATIONS
AFTER EVERY 10 HOURS OF USE IF THE
VACUUM CLEANER PURCHASED IS ATEX
41