AKO PROPlus 3PH BASIC Guide Rapide page 26

Masquer les pouces Voir aussi pour PROPlus 3PH BASIC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Configuring digital input 1
0= Off
P10
3= Severe external alarm
6= Remote defrost
Configuring digital input 2
0= Off
P11
3= Severe external alarm
6= Remote defrost
Digital input polarity 1
P12
0=Energised on closed contact, 1=Energised on open contact
Digital input polarity 2
P13
0=Energised on closed contact, 1=Energised on open contact
Maximum start-up time after pump down
P14
(Values between 1 and 9 seconds are not accepted) (0=Disabled)
P15 Maximum pump down time (0=Disabled)
P22 Cold room light timer
P23 Stop fans and compressor on opening door
P24 Start up delay for fans and compressor with door open
EP Exit Level 1
Nivel 1.-
ACCESS CONTROL AND INFORMATION
L5 Access code (Password)
PU Program version (Information)
Pr Program revision (Information)
EP Exit Level 1
Default parameters according to models
Modelos
AKO-15690/1/2/3
AKO-15697
AKO-15699
AKO-15690/1/2/3-EVC
AKO-15697-EVC
AKO-15699-EVC
Description
1= Door contact
2= External alarm
4= Change Set Point
5= Continuous cycl
1= Door contact
2= External alarm
4= change Set Point
5= Continuous cycl
0=No
(tid)
Description
P11
0=Deactivated
0=Deactivated
2=Same compressor status
2=External alarm
2=Same compressor status
0=Deactivated
0=Deactivated
2=External alarm
26
Units
e act.
e act.
(sec.)
(min.)
(min.)
1=Si
(min.)
Units
Parameter
P6
1=Pump down
0=Deactivated
0=Deactivated
0=Deactivated
1569H051 Ed.01
Min
Def
Max.
0
0
6
*
0
6
0
1
1
0
0
1
0
0
120
0
0
15
0
0
999
0
0
1
0
0
999
Min
Def
Max.
0
0
99
-
-
P62
1=Alarm
1=Alarm
1=Alarm
4=Pump down
2=Same compressor status
2=Same compressor status

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

1569 série1569 -evc série15691156921569315697 ... Afficher tout

Table des Matières