5. POSITIONING THE LOCK
35mm
6. FIXING THE LOCK
IMPORTANT: Do not close the door before BEING SURE the code works properly.
The square is planned for 35 to 65 mm
thick door.
For lower than 50 mm thick doors,
separate a size of 12 mm at the end of the
square.
Cut the end of the attachment screws
according to the thickness of the door so
that with the flanges the screws hold the
lock with three threads
CAUTION: lThe lower attachment screw
is longer than the upper screw.
Hold the lock into position, the rear face and the neoprene flanges on the door with the square into
position.
Screw all the elements starting by the upper screw.
IMPORTANT:
Determine
(flush-mounted or surface-mounted) and mark its position
on the frame before drilling the door.
CAUTION: The bolt is 35 mm taller regarding the side of
the lock.
Present the internal block with the handle in vertical
position and hold it on the door with an end of the bolt
aligned with the frame where the strike will be installed
(see step 7).
Mark the position of the upper mounting hole using the
template at the back of the instruction manual and mark
the position of the lower mounting hole and the hole for
the square.
Drill 7 mm holes for the attachment screws and one
9.5 mm hole for the square.
5EN
the
strike
to
use