Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal
pressures.
Installation Instructions
• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• 71284000: The mixer can not used together with a
continuous flow water heater.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 32)
Flow diagram (see page 32)
Spare parts (see page 36)
Cleaning (see page 37)
Fault
Insufficient water
Mixer stiff
Mixer dripping
Water escaping in area of swivel
spout
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Cause
- Aerator calcified, dirty
- Shut-off unit damaged
- Shut-off unit damaged
- O-ring defective
Assembly (see page 33)
English
Operation (see page 35)
Test certificate (see page 35)
65°C
Remedy
- Clean aerator, replace as
necessary
- Exchange shut-off unit
- Exchange shut-off unit
- Exchange O-ring