ENERGY TOP B
If the Remote Timer Control (optional) is connected to the boiler, the above ad-
A
justments are managed according to that given in table 1.
Table. 1
Heating temperature adjustment Adjustment can be made from the Remote Timer Control menu and the boiler
control panel.
DHW temperature adjustment
Adjustment can be made from the Remote Timer Control menu and the boiler
(with optional hot water tank
control panel.
installed)
Summer/Winter Switchover
Summer mode has priority over a possible Remote Timer Control heating
demand.
Eco/Comfort selection (with
On disabling DHW from the Remote Timer Control menu, the boiler selects the
optional hot water tank installed)
Economy mode. In this condition, the button detail 7 - fig. 1 on the boiler panel
is disabled.
On enabling DHW from the Remote Timer Control menu, the boiler selects the
Comfort mode. In this condition it is possible select one of the two modes with
the button detail 7 -fig. 1.
Sliding Temperature
Both the Remote Timer Control and the boiler card manage Sliding Tempera-
ture adjustment: of the two, the Sliding Temperature of the boiler card has prior-
ity.
System water pressure adjustment
The filling pressure with the system cold must be approx. 1.0 bar. If the system pressure
falls to values below minimum, the boiler card will activate fault F37 (fig. 14). Flashing of
the arrows (details 18 and 24 - fig. 1) together with the error code indicates which boiler
shell is in fault status.
fig. 14 - Low system pressure fault
Once the system pressure is restored, the boiler will activate the 120-second
A
air venting cycle indicated on the display by FH.
eco
reset
comfort
cod. 35401H060 - Rev. 01 - 02/2018
3. INSTALLATION
3.1 General Instructions
THE BOILER MUST ONLY BE INSTALLED BY QUALIFIED PERSONNEL, IN COMPLI-
ANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL MANUAL, THE
PROVISIONS OF CURRENT LAW, THE NATIONAL AND LOCAL REGULATIONS,
AND THE RULES OF PROPER WORKMANSHIP.
ENERGY TOP B is a heat generator arranged to operate alone or in cascade (bank).
When two or more generators are installed in cascade with the original kits ENERGY
TOP B, respecting the prescriptionsFERROLIof this manual, they can be considered as
a single heat generator of total power equal to the sum of the powers of all the units con-
nected in cascade.
All the requirements of the current standards and regulations applicable to this "equiva-
lent" total heating capacity generator must be met. In particular, the place of installation,
safety devices and fume exhaust system must be adequate for the total heating capacity
of the bank of units.
In fact, each ENERGY TOP B is a complete and independent heat generator, equipped
with its own safety devices. In case of overtemperature, no water or no circulation in the
unit , the protection devices cause the unit to shutdown , preventing its operation.
The installation instructions given in the following paragraphs concern single units and
connection in cascade.
Given below are the possible configurations for connection in cascade.
Configurations in line
fig. 15 - Configuration - in line (example with 4 modules)
Table. 2 - Configurations in line
Heating power
max.
Model
Model
kW
Module 1
Module 2
75
80
/
116
125
/
150
160
232
250
225
160
80
266
160
125
307
250
80
348
250
125
300
160
160
382
250
160
464
250
250
375
160
160
416
160
160
457
250
160
498
250
160
539
250
250
580
250
250
450
160
160
532
250
160
614
250
250
696
250
250
525
160
160
566
160
160
607
250
160
648
250
160
689
250
250
730
250
250
771
250
250
812
250
250
600
160
160
682
250
160
764
250
250
846
250
250
928
250
250
1003
250
250
1044
250
250
1078
250
250
1160
250
250
A
Combinations
Model
Model
Model
Module 3
Module 4
Module 5
/
/
/
/
/
/
/
/
/
200
/
/
/
200
/
/
/
200
/
/
/
200
/
/
/
200
/
/
/
200
/
/
/
200
/
/
/
200
/
/
/
200
80
/
/
200
125
/
/
200
80
/
/
200
125
/
/
300
80
/
/
300
125
/
/
300
160
/
/
300
160
/
/
300
160
/
/
300
250
/
/
300
160
80
/
300
160
125
/
300
160
80
/
300
160
125
/
300
160
80
/
300
160
125
/
300
250
80
/
300
250
125
/
300
160
160
/
300
160
160
/
300
160
160
/
300
250
160
/
300
250
250
/
300
250
250
80
300
250
250
125
300
250
250
160
300
250
250
250
300
EN
Ø;
A
/
500
/
500
1000
1000
1500
1500
1500
1500
2000
2000
2000
2500
2500
2500
2500
2500
2500
3000
3000
3000
3000
3500
3500
3500
3500
3500
3500
3500
3500
4000
4000
4000
4000
4000
4500
4500
5000
5000
73