ZSB−1/8
9
Care and maintenance
Maintenance
Check every month to be sure that the product is functioning correctly by
S
applying a pressure of 2.8 bar with switched pressure sequence valve as
described in chapter 7.
Cleaning
1. Exhaust the complete system and the product.
2. Unscrew the filter element 5. Do not lose the seals when doing this.
3. Clean the components of the product exclusively with the cleaning agents
specified as per Fig. 7.
Component
Housing
Screw with filter
element 5
Silencers
Fig. 7
4. Screw in again the screw with filter element 5, max. tightening torque 4 Nm.
10
Accessories
Designation
Service units
Front panel valve
Pushbutton actuator
Mushroom pushbutton
Silencers
Pressure sequence valve
Fig. 8
20
Cleaning agent
Water (max. +60 °C)
Compressed air
Water (max. +60 °C)
Petroleum ether
Type
MSB..., LFR−...−D−...
SV−3−M5
T−22−SW, T−30−SW
P−22−SW, P−30−SW
U−x
VD−3−PK−3
Cleaning interval
if required
half yearly or
after every 100 000
switching cycles
Festo ZSB−1/8 0701NH English