1. Use a flat bladed screwdriver to shut off the hot and cold water supply
at the service stops.
2. Remove the o-ring and temperature stop.
3. Unscrew the bonnet and remove valve stem.
4. Use needle nose pliers to remove valve cartridge.
5. Apply silicone grease to new cartridge where indicated and install into
valve body.
6. Replace valve stem with arrow pointing UP (for reversed inlet
installations, arrow should point DOWN), and reinstall bonnet.
7. Restore hot and cold water supply by opening service stops.
8. Follow maximum temperature adjustment procedure
Bonnet
Temperature
Stop
O-Ring
CARTRIDGE REPLACEMENT
Valve Cartridge
6
Valve Body
Grease
Valve Stem
on Page 5.
Service Stops