Lincoln Quicklub V10-V13 Instructions De Service page 39

Masquer les pouces Voir aussi pour Quicklub V10-V13:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Subject to modifications
1A7.16: Socket with 10 m cable, 6-core for power supply 24 VDC,
& to connect the illuminated pushbutton (for additional lubrication and functional test), the machine contact and the signal lamp in case of low-level indication
15
- Power supply + 24 VDC via machine contact
30
- + 24 VDC
31
- – 0 VDC
M
- Electric motor
A
- Control p.c.b. V20-V23
B
- Pump housing
C
- Connection plug 1A7.16 at pump housing
D
- Socket X1
F
- Machine contact
Connection X1 Bayonet plug DIN 72585-1 (left) 1A7.16
G
- Fuse 10 A
H
- External illuminated pushbutton
N
- Level control
O
- external signal lamp in case of low-level indication
Z
- Operational test / additional lubrication
br
- brown
gb
- yellow
sw
- black
ws
- white
rt
- red
bl
- blue
gr
- grey