Make Gas Connection; Connect Vent; Level Dryer - Maytag W10088775 Guide D'utilisation Et D'entretien

Sécheuse à gaz
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MAKE GAS CONNECTION

1. Remove the red cap from the gas pipe.
2. Using a wrench to tighten, connect the gas supply to the dryer. Use pipe-joint compound
on the threads of all non-flared male fittings. If flexible metal tubing is used, be sure there
are no kinks.
A
A. Flared male thread
B. Non-flared male thread
NOTE: For LP gas connections, you must use pipe-joint compound resistant to the action
of LP gas. Do not use TEFLON
®†
tape.
A combination of pipe fittings must be used to connect the dryer to the existing gas line.
Shown is a recommended connection. Your connection may be different, according to the
supply line type, size, and location.
A
B
³⁄₈
A.
" flexible gas connector
³⁄₈
B.
" dryer pipe
³⁄₈
³⁄₈
C.
" to
" pipe elbow
³⁄₈
D.
" pipe-to-flare adapter fitting
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
12
3. Open the shutoff valve in the supply line. The valve is open when the handle is parallel to
B
4. Test all connections by brushing on an approved noncorrosive leak-detection solution.
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible gas line.
4. Once the exhaust vent connection is made, remove the corner posts and cardboard.
Check the levelness of the dryer. Check levelness first side to side, then front to back.
D
C
If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs
up or down and check again for levelness.
the gas pipe.
A
A. Closed valve
B. Open valve
Bubbles will show a leak. Correct any leak found.

CONNECT VENT

existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust
outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a
4" (10.2 cm) clamp.

LEVEL DRYER

B

Publicité

Table des Matières
loading

Table des Matières