Scope Of Supply; Overview Of The Parts - Gossen MetraWatt SIRAX V 644 Mode D'emploi

Convertisseur de mesure universel
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operating Instructions
Universal Transmitter SIRAX V 644
Contents
1. Read first and then ... ............................................... 22
2. Scope of supply ........................................................ 22
3. Overview of the parts ................................................ 22
4. Brief description ........................................................ 23
5. Technical data ........................................................... 23
7. Electrical connections ............................................... 26
8. Programming the transmitter .................................... 28
9. Withdrawing and inserting the device ....................... 29
10. Mounting ................................................................... 29
11. Commissioning ......................................................... 30
12. Maintenance ............................................................. 30
13. Releasing the transmitter .......................................... 30
14. Dimensional drawing ................................................. 30
1. Read first and then ...
The proper and safe operation of the device
assumes that the Operating Instructions are
read and the safety warnings given in the
various Sections
6. Mechanical coding of the plug-in
module
7. Electrical connections
8. Programming the transmitter
11. Commissioning
are observed.
The device should only be handled by
appropriately trained personnel who are
familiar with it and authorised to work in
electrical installations.

2. Scope of supply

Transmitter (1) (incl. plugged sets of codes)
Order Code: Significance of the 2nd. and 3rd. digits
644-6 x x
1 Standard, measuring input not I.S.,
power supply 24... 60 V DC/AC
2 Standard, measuring input not I.S.,
power supply 85...230 V DC/AC
3 [EEx ia] IIC, measuring input I.S.,
power supply 24... 60 V DC/AC
4 [EEx ia] IIC, measuring input I.S.,
power supply 85...110 V DC / 85...230 V AC
1 Standard climatic rating;
instrument without cold junction compensation
22
3 Data cards (2) (for recording programmed settings)
1 Coding camb (3)
(for coding the backplane SIRAX BP 902)
1 Ex approval (4) (only for Ex version devices)
1 Operating Instructions (5) in three languages: English,
French and German
(5)
(1)
Betriebsanleitung
Universal-Messumformer SIRAX V 644
Mode d'emploi
convertisseur de mesure universel
SIRAX V 644
Operating Instructions
Universal Transmitter SIRAX V 644
V 644-6 B d-f-e
107 947
1000-04.97
Aargauerstrasse 7
CH-5610 Wohlen/Switzerland
Telefon +41 56 618 21 11
Telefax +41 56 618 24 58
Camille Bauer AG
Telex 827 901 cbm ch
Fig. 1

3. Overview of the parts

Figure 2 shows those parts of the transmitter of consequence
for mounting, electrical connections, programming con-
nections and other operations described in the Operating
Instructions.
Konfiguration / Configuration SIRAX V 644
Konfiguration / Configuration SIRAX V 644
Anlage/Mess-Stelle
Plant/Measuring point
Messeingang
Measuring input
Fühlertyp
Sensor type
Anlage/Mess-Stelle
Plant/Measuring point
Temperatur-Messbereich
Temperature range
Messeingang
Measuring input
Messausgang
Measuring output
Fühlertyp
Sensor type
Anfahr-Festwert währ. 5 s
Start up value during 5 s
Temperatur-Messbereich
Temperature range
Einstellzeit
Setting time
Messausgang
Measuring output
Bruchsignalisierung
Open-circ. superv.
inactive
active
Anfahr-Festwert währ. 5 s
Start up value during 5 s
Netzbrumm-Unterdrückung
Mains ripple suppression
50 Hz
60 Hz
Einstellzeit
Setting time
Grenzwertfunktion
Output contact
inactive
active
Bruchsignalisierung
Open-circ. superv.
inactive
active
Netzbrumm-Unterdrückung
Mains ripple suppression
50 Hz
60 Hz
Grenzwertfunktion
Output contact
inactive
active