Suggested wire length relative to strain relief
4
/
"
1
2
(114.3 mm
21.
Connect ground wire
Route power cord through strain relief in the back of the terminal
box. Remove the ground connector screw on the raised floor
inside the box and place it through the ring terminal of the green
ground wire of power cord. Reattach and tighten the ground
connector screw to the raised floor of the box.
22.
Connect remaining wires
White wire
White wire
Black wire
Select UL Listed/CSA Approved power cord for the Dishwasher.
Power Cord Kit
Kit typically includes power cord, metallic strain relief, grommet.
(Whirlpool Part Number Cord Kit - Straight - W11365011
Cord Kit - Right Angle - W11365014)
To connect wires with ring terminals, remove the screws from the
terminal block, place the screw through the ring terminals, and
reattach screws back into the terminal block.
To connect wires without ring terminals, remove the screws from
the terminal block, push the wire ends under the screw heads, and
tighten the screws.
NOTE: Pre-tinned wires should not be used when connecting to
the terminal block.
)
0.75" - 1"
(19 mm - 25 mm)
Ground connector
screw
Ground
Washer
wire
Ground
screw
Ground wire
Black wire
Wiring configuration
23.
Secure cord or wire on strain relief
Tighten strain relief screws to secure cord.
24.
Reinstall terminal box cover and wires
Place wires inside terminal box. Replace the cover by inserting
the hooks of the terminal cover into the slots in the floor of the
terminal box and sliding the cover tight against the back wall
where wires come in. Make sure wires are tucked inside the box
and not pinched by the cover.
Put the terminal box back on the crossbar and push to the right
so terminal box snaps into the plastic side member.
NOTES:
Once the terminal box has been remounted on the dishwasher,
■
tuck any excess length or slack over nearby components to
help keep them off the floor.
Route cord out the rear of the dishwasher so that it does not
■
touch dishwasher motor or lower part of dishwasher tub.
Do not plug cord into an outlet until instructed to do so.
■
A maximum of 2 power cord supply conductors (12 AWG
■
largest size) plus 1 grounding conductor are permitted in the
terminal box.
IMPORTANT: NO ADDITIONAL CONNECTIONS OTHER THAN
DISHWASHER POWER CONNECTION ARE TO BE MADE INSIDE
THE DISHWASHER TERMINAL BOX.
Terminal
box cover