INSTALLATION
Installing the Unit
550 mm
(21-11/16")
344 mm
(13-9/16")
RCTHW-1B
NOTE: The countertop must be level to ensure proper draining
of the rectangular well.
NOTICE
Remote mounted control panels must have a minimum
152 mm (6") clearance from unit (not to exceed 1420 mm
[56"]). Mounting control panel closer may cause heat
damage to electrical system in control panel.
The remote mounted control box should be installed outside
of heat zone. Locating the control box inside heat zone will
cause the control(s) to overheat, malfunction, and fail.
33 mm
(1-5/16")
65 mm
(2-9/16")
Ø 4,5 mm
(3/16")
NOTE: The electrical cord between the unit and the control box
is 1420 mm (56 ) in length.
305 mm
12"
RHW-1B
144 mm
(5-9/16")
132 mm
(5-1/8")
154 mm
(6")
Control
Screw
Box
Front
Cover
Control Box
Cutout
NOTICE
Do not use excessive force when
tightening mounting screws on
built-in units. This may damage unit
and/or countertop.
Installing the Remote Mounted Control Box (RMB)
Control Box Housing
Front
Cover
Front
Cover
Screws
Countertop
Cutout
Countertop
Top Flange
Screw
Screw
L Bracket
L Bracket
Mounting
Flange