11.3

Acknowledge fault

General
6.0.0.0
E000
6.0.0.0
10
1/1
Fig. 42: Navigation in the event of an error
11.3.1 Error type A or D
1
2
3
4
Fig. 43: Error type A, flowchart
104
E000
5.0.0.0
S
In the event of an error, the error page is displayed instead of the sta-
tus page.
In this case, the following procedure can generally be used for naviga-
tion (Fig. 42):
• To change to the menu mode, press the red button.
Menu number <6.0.0.0> flashes on the display.
By turning the red button, it is possible to navigate in the menu as
usual.
• Press the red button.
Menu number <6.0.0.0> appears steady on the display.
On the units display, the current incidence (x) as well as the maximum
incidence of the error (y) are displayed in the format "x/y".
Until the error can be acknowledged, pressing the red button again
will cause a return to menu mode.
NOTE:
A 30-second time-out causes the display to revert to the status page
or error page.
NOTE:
Each error number has a separate error counter that counts incidences
of the error within the last 24 hours. The error counter is reset after
manual acknowledgement, 24 hours after "Mains on" or after a
repeated "Mains on".
Error type A (Fig. 43):
Program
Contents
step/query
1
• Error code is displayed
• Motor Off
• Red LED On
• SSM is activated
• Error counter is incremented
2
> 1 minute?
3
Error acknowledged?
4
End; auto control resumes
Yes
No