CAUTION! Risk of property damage!
• In the case of pumps that have been fitted or retrofitted with
a plug-in module, the passage of air to the module must not
be restricted.
• The gasket may be damaged when the motor housing is
turned. Replace defective gaskets immediately!
7.2

Electrical connection

DANGER! Risk of fatal injury!
Incorrect electrical connections can cause fatal electric
shocks.
• Have the electrical connection set up by an electrician
approved by the local electricity supplier only and in
accordance with local regulations.
• Disconnect the power supply before any work.
• The current type and voltage of the mains connection must
correspond to the details on the rating plate
• The electrical connection must be made in accordance with
VDE 0700/part 1 (CH: NIN 2010) via a fixed connecting cable,
which is provided with a plug device or an all-pole switch with
a contact opening width of at least 3 mm.
• Maximum back-up fuse: 10 A, slow-blow
• To ensure drip protection and strain relief at the PG screwed
connection, a connected load with an adequate outer diameter
is necessary (e.g. H05VV-F3G1.5).
• The connection line is to be installed in such a way that it can-
not under any circumstances come into contact with the pipe
and/or the pump and motor housing.
• Make the mains connection according to fig. 6.
• The connection cable can be taken through the cable feed-in right
or left. Exchange dummy plugs and cable feed-in as necessary.
When the terminal box is positioned laterally, always arrange the
cable feed-in from below (fig. 5).
Installation and operating instructions Wilo-Star-Z/-ZD
English
33