BFT RIGEL 5 Instructions D'utilisation Et D'installation page 22

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
Photocells on
photc.
OFF
opening
open
OFF
Rapid closing
fast cls
OFF
Photocell test
test phot
Electric edge
OFF
test bar
test
Photocell test
test phot
OFF
on opening
op.
Photocell test
test phot
OFF
on closing
cl.
OFF
Master/Slave
aster
fixed
OFF
Fixed code
code
Radio transmit-
radio
ON
ter program-
prog
ming
OFF
Time count
ti e. c.
zone
OFF
Courtesy light
light
Clock / Pede-
OFF
clock ped
strian
light-
ON
Light/Alarm
alar
OFF
1 active motor
1
ot. on
Gate-open or 2nd
OFF
radio channel
sca-2ch
warning light
ON
Safety edge
bar
Blink ing ou-
OFF
blink
tput
suction-
OFF
Type of lock
type
10.3) TABLE C: RADIO MENU (RADIO)
Logic
Description
Add Start Key
Add start
associates the desired key with the Start command.
Add 2ch Key
add 2ch
associates the desired key with the 2nd radio channel command.
Erase List
erase 64
WARNING! Erases all memorized remote controls from the receiver's memory.
Read receiver code
Displays receiver code required for cloning remote controls.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time the
W LINK remote control is last pressed.
OFF= W LINK programming disabled.
22 -
RIGEL 5
INSTALLATION MANUAL
In case of obscuring, this excludes photocell operation on opening.
ON
During the closing phase, it immediately reverses the motion.
In case of obscuring, the photocells are active both on opening and on closing. When a photocell is obscured
OFF
on closing, it reverses the motion only after the photocell is disengaged.
Closes the gate after photocell disengagement, before waiting for the end of the TCA (automatic closing time)
ON
set.
OFF
Command not entered.
ON
Activates photocell check (see Fig. D)
OFF
Deactivates photocell check
ON
Activates electric edge check (see Fig. D)
OFF
Deactivates electric edge check
ON
Enables the test of the active photocells on opening.
OFF
Desables the test of the active photocells on opening.
ON
Enables the test of the active photocells on closing.
OFF
Desables the test of the active photocells on closing.
ON
The control panel is set as Master in a centralised connection (see "SCS OPTIONAL MODULES").
OFF
The control panel is set as Slave in a centralised connection (see "SCS OPTIONAL MODULES").
ON
The receiver is configured for operation in fixed-code mode.
OFF
The receiver is configured for operation in rolling-code mode.
This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2, T3 or T4) of a transmitter already memorised
in standard mode by means of the radio menu.
ON
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2, T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new transmitters can be entered before the end
of this time.
This mode does not require access to the control panel.
This disables transmitter storage via radio.
OFF
The transmitters can only be memorised using the appropriate Radio menu.
Clones and replays are not accepted.
ON
The control unit calculates the activation time of each motor, based on the preceding manoeuvres.
The control unit activates the motors at each manoeuvre for the time set. N.B. Always set the operation time to a
OFF
slightly higher value than needed to carry out the complete manoeuvre.
ON
Zone light. Remains active as long as the manoeuvre lasts.
Courtesy light. Remains active for 90 seconds after last operation.
OFF
N.B. These settings cannot be used if the blinker output is set to ON.
Input for the connection of an external timer.
The Clock input is only active in Motor 2, for the pedestrian time set.
ON
A start command given during the clock phase carries out complete gate opening and closing, resetting the
open pedestrian position.
OFF
The Clock input acts on both motors.
ON
Gate-open alarm output (activated if the gate remains open for twice the TCA time set).
OFF
Stair-light control (the impulse stays on for 1 second).
ON
Only motor 2 activated (1 leaf ).
OFF
Both motors are activated (2 leaves).
The output between terminals 18 and 19 is configured as Gate-open warning light, in this case the 2nd radio
ON
channel controls pedestrian opening.
OFF
The output between terminals 18 and 19 is configured as 2nd radio channel.
ON
Input of terminals 36-37 is active as input for the safety edge.
OFF
Input of terminals 36-37 is active as input for opening photocells.
Set the output at terminals 12-13 ("courtesy light") as blinking output (active only during leaf movement). N.B.
ON
Any setting relating to the "courtesy light" function is ignored.
Keep the output at terminals 12-13 as "courtesy light" or "zone light".
WARNING! It is not possible to use the SSR5 board in motor preheating mode and at the same time have the
OFF
Zone light/Courtesy Light and Blinker/Electric lock on. In this case, outputs 10-11 cannot be used and outputs
12-13 can only be used for one of the two functions.
ON
Suction-type lock. Enabled with gate closed.
OFF
Click lock. Enabled with a pulse at each opening.

Publicité

Table des Matières
loading