Direct Voltage (V/Dc); Alternating Voltage (V/Ac) - VOLTCRAFT VC-750E Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

a) Direct voltage (V/DC)
Range
6.000 V
60.00 V
600.0 V
600 V overload protection; Impedance: 10 MΩ
Specified measuring range: 5 – 100 % of the measuring range
b) Alternating voltage (V/AC)
Range
6.000 V
60.00 V
600.0 V
600.0 V "LoZ"
600.0 V "Motor"
Frequency range: 40 Hz – 1 kHz ; 600 V overload protection; Impedance: 10 MΩ (LoZ: 300 kΩ)
Specified measuring range: 5 – 100 % of the measuring range
The multimeter may display ≤5 counts if a measuring input is short-circuited.
After using the LoZ feature, leave the multimeter for 1 minute before using it again.
TrueRMS peak (Crest Factor (CF)) ≤3 CF to 600 V
TrueRMS peak for non-sinusoidal signals plus tolerance
CF >1.0 – 2.0
+ 3 %
CF >2.0 – 2.5
+ 5 %
CF >2.5 – 3.0
+ 7 %
Criteria for phase detection in "Motor" mode: >80–600 V/AC, 50–80 Hz
68
Resolution
0.001 V
0.01 V
0.1 V
Resolution
0.001 V
0.01 V
0.1 V
0.1 V
0.1 V
Accuracy
±(0.6 % + 3)
±(0.9 % + 6)
Accuracy
±(1.0 % + 6)
±(2.5 % + 6)
±(2.0 % + 6)