Minimum required liquid level

Minimum required liquid level at the suction nozzle must be more than 3 x the diameter of
the suction pipe.
Figure 3:
Minimum required luiquid level.

Minimum back pressure

The MDR-series demands a certain head for good function.
Minimum head = 0,5 m wc or 0,05 bar manometric pressure. If less, install a valve in the
discharge pipe to adjust head.
1
Figure 4:
Minimum back pressure (1 = pump).

Min flow required

To cool and lubricate the impeller bearing and shaft a certain flow is required through the
pump.
Min. flow
l/min
MDR45
3
MDR75
5
MDR85
7
MDR105
10
MDR116
10

Temperature range

P2 (PVDF) = -10°C - +100°C
P3 (PP) = -10°C - + 85°C
Technical information
Max. system pressure
bar (20°C)
3
3
3
3
3
11