SLV Lighting North America
ENGLISH
OPERATING MANUAL FOR
OUTDOOR FIXTURE
SQUARE POLE 30/60/90
232236U/46U/49U
1.
NOTES ON SAFETY
Life-threatening danger due
to electric shock, danger of fire and danger
from falling objects may exist if the following is
not respected!
This luminaire must be installed in accordance
with the National Electric Code, Canadian
Electrical Code, State, provincial, and local
regulations by a licensed electrician.
Installation, mounting or works on the electrical connection may
only be carried out by a licensed electrician.
Do not cover the product - provide free air circulation!
Do not hang or fasten anything on the product, especially no
decoration.
Keep children away from the product.
The luminaire may only be operated with an intact protection glass.
Operate the product only when it functions properly:
In case of a malfunction do NOT touch the product or operate it further.
Disconnect the product from the power supply by an external switch or
by the fuse.
If touched or further operated there is danger from electric shock,
burning, or fire.
A malfunction exists when:
Visible damages appear.
The product does not work properly (e.g. flickering).
Smoke, steam or crackling sounds appear.
Smell of burning is recognisable.
An overheating is recognizable (e.g. by discolouration of adjacent
surfaces).
Operate the product only after maintenance and examination by a
licensed electrician!
2.
USE AS DIRECTED
This product is exclusively for lighting purposes and may:
Only be used with a voltage of 120V ~60Hz.
Only be operated when firmly mounted.
Not be exposed to strong mechanical loads or to strong
contamination.
Only be installed and operated after a condition inspection if the
product is dirty or has been moistened through storage.
Not be modified or converted.
3.
OPERATION
Exchange the light source always before it reaches its lifespan, to avoid
personal injuries, or damages of the fixture or other objects.
Disconnect the product from the power supply, before you exchange
the bulbs. Let the light source cool down before replacement.
There exists danger of burning!
Use only light sources that are approved for the product. Approved light
sources are indicated on the type label.
Other types of light sources may cause fire risk, damage the product
or lead to malfunction.
Replacing the light source: Remove the screws beneath the head of
the fitting. Pull off the head. Remove the lamp head. Screw the bulb into
the socket. Assemble the fixture in reverse order.
Check and clean the gasket after each opening of the fixture. The
bearing surface of the gasket must be free of dirt. These measures
ensure that the IP class is maintained.
Note the proper fit for the gasket.
4.
MAINTANANCE AND CARE
The following environmental influences may have unwanted effects
on the surface of the product:
acid rain and sour soil
high salt content in the air
thawing salt
cleaning agents
fertilizer especially in flowerbeds
other chemical substances (e.g. herbicides)
Protect the product by adequate means to avoid unwanted changes of the
surface.
Disconnect the product from the power supply and let it cool down,
before you clean the product.
If disregarded there may be danger of electric shock or by burning
when cleaning the product.
Cleaning: Clean the product on a regular basis using a slightly
moistened, soft and fluff-free cloth. Please also note additional supplied
notes on maintenance and care.
5.
ADDITIONAL IMPORTANT NOTES
Storage: The product must be stored in a dry and clean environment. Do
not strain the product mechanically during storage.
Warranty: In case of a warranty contact your dealer.
6.
INSTALLATION (only by a licensed electrician)
Switch off the 120V power (mains) and external switch before doing
any work
Mortal danger may occur from an electric shock
Use only parts, which are supplied with the product or are described as
accessories!
Otherwise the product or the whole installation may not be secure.
Danger for life or danger of fire may exist!
Inspect the product for loose parts inside the housing. When there are
loose parts inside the housing and these are not explicitly described as
accessories the product may not be installed or operated.
The housing may be voltage-carrying. Danger of electric shock!
Use the supplied fastening material only when it is suited for the
installation background. If this is not the case use only fastening material
suiting the installation background.
When using fastening material that is not suitable there may be
danger from falling objects.
Unpacking
Carefully take the product out of the packaging removing any transport
safeguards.
Before disposal of the packaging material make sure that all
components of the product are removed.
Installation place
The product is suited for floor installation.
Choose a place where the installation is not a source of danger (e.g.
stumbling, knocking).
Make sure that the product is mounted on a stable, even and tilt-fixed
background.
Separate Installation Steps
Notice: Do not try to seal the product yourself, using additional silicon or
another sealant.
There are three different types of mounting:
1) Screw-set (Consignment): Screws, plug for direct mounting of the
product.
2) Concrete anchor (Art. no.: 232220U): For casting into liquid concrete,
including thread and nut.
3) Earth-spike (Art. no.: 232221U): To fasten the spot in the soil, incl.
thread and nut.
Determine the place of installation and mark the holes to be drilled. Note
that the cable outlet of the mains supply corresponds with the cable inlet
of the fitting. Do not damage the power supply line, e.g. by drilling,
screws or strong bending.
Disassemble the fitting as shown on the figure.
Electrical Connection
The product must be able to be separated by an external switch and
electrical circuit breaker from the 120VAC supply.
Switch off 120VAC power before doing any work!
Connect the black wire (live conductor), the white wire (neutral
conductor) and the green wire (protective ground conductor) of the
120VAC (mains) supply with the corresponding wires of the luminaire.
Black (L), White (N), and GRND (Green) wires.
Now fasten the canopy back to the mounting bracket. Do not forget to
apply the toothed washers!
Inserting the light source: Touch energy-saving-lamps on the plastic
housing, not on the bulb glass. Screw the bulbs into the socket.
Check if the product functions properly and is securely fixed.
The product is now ready for operation.
232236U/46U/49U 08/2013
© SLV Lighting North America