2.3
Igniting the pilot light and burner
DANGER! Risk of explosion
D Do not switch on the appliances if you smell gas in the installation room! Risk of explosion!
Immediately close the gas shut-off device at the customer location! Do not switch electrical
appliances On or Off! Open windows and doors! Thoroughly air out the installation room by
providing a draught! Leave the room! Notify the emergency service of the gas grid operator!
Determine the location of the gas leak after adequate air exchange has taken place!
Ventilation slits
Piezo spark
ignition for left
pilot burner
Gas tap
Gas control for
left burner
. After igniting the pilot light, keep the gas control pressed down for approx. 5 - 10 seconds
− so that the thermal element can sufficiently heat up and
− the gas supply is not automatically shut off again (automatic safety pilot).
Setting the burner light
. Release the gas control after the ignition procedure and turn onto a high heating capacity.
. To change the setting from a large to a small flame, press in the gas control and turn to a
small flame. The temperature range between a large and small flame is continuous.
D Low heating capacity, small flame symbol
D High heating capacity, high flame symbol
. Repeat ignition procedure for the second burner.
Keep burner ready for operation
. If the appliance is not required for a short amount of time, turn the gas control to "pilot light"
.
D The burner flame goes out and the pilot light continues to burn.
Note on safety pilot
D The appliance is not fitted with a thermoelectrical safety pilot. When extinguishing the pilot
light, the gas supply is automatically interrupted by the safety pilot, thus preventing an unin
tentional leakage of the gas.
Piezo spark
ignition for right
pilot burner
Gas control for right burner
. Open the customer gas tap (main shut-off
device).
. Open the gas tap.
D When the appliance has not been used for a
longer period of time: e. g. the main shut-off
device was closed, it may take slightly
longer before the pilot light ignites (the gas
supply has to fill up with gas again).
. Press in gas control, turn to ignition symbol
and keep pressed down.
D The gas for the pilot light escapes.
. Continue pressing button for Piezo spark
ignition until the pilot light starts to burn.
D The pilot light can be controlled by means of
the ventilation slits in the collecting tray.
en
23 / 76