AGF-PV-30, AGF-PV-S2, AGF-T-30, K-
AGF-PV-30, RAF-PV-30, ADF-PV-30
Cleaning
Dust deposits on the filter must be removed regularly.
Clean the outside of the filter using only a clean, damp cloth
(do not use cleaners containing solvents).
DANGER
Spark formation due to electrostatic discharge (explo-
sion hazard)
Only clean the filter with a clean, damp cloth.
4 Transport and storage
Only transport the product inside the original packaging or a
suitable alternative.
The equipment must be protected from moisture and heat
when not in use. They must be stored in a covered, dry and
dust-free room at a temperature between -20 °C to 50 °C (-4 °F
to 122 °F).
5 Installation and connection
5.1 Installation site requirements
Always use washers on the longitudinal slots when installing
the retaining ring flange. Furthermore, verify the filter has
been inserted all the way to the end of these longitudinal
slots.
The filter should be installed in a way so the filter element can
be replaced. If the filter protrudes from a contour, please note
this poses a risk of damage.
The maximum gas temperature is 100 °C.
The maximum permissible pressure is 4 bar abs.
Please refer to chapter Design types for information about the
use in explosive areas.
5.2 Connecting the gas lines and the condensate drain
The connections must be made carefully and properly using
suitable fittings, and tightened hand-tight.
Please check if your version has G-threads or NPT threads. On
the latter, the item number on the nameplate is followed by
"I".
An arrow on the filter indicates the flow direction.
When not using the condensate drain, close the opening with
a sealing plug.
On special versions without union nut and/or seal on the con-
densate drain, the operator must ensure proper sealing. We
recommend using a PBTP union nut (GL25 thread) and a silic-
one seal with PTFE sleeve at one end.
8
Bühler Technologies GmbH
The head of the filters can be rotated to switch the inlet and
outlet sides (type RAV... inlet only).
Perform a leak test with suitable means.
5.3 Connecting a bypass or moisture detector
NOTICE! Not for AGF-T-30. not expedient with RAF-PV-30.
The filter head has a G1/4 female thread, factory sealed with a
plug, for installing a bypass or moisture detector.
• To use the thread, unscrew the plug and screw in the fit-
• Perform a leak test with suitable means.
6 Operation and control
The device must not be operated beyond its specifications.
7 Service and Repair
Please refer to the original operator's manual on the included
CD or online at www.buehler-technologies.com for a detailed
description of the unit including information on
troubleshooting and repair.
8 Maintenance
Always observe the applicable safety- and operating regula-
tions when performing any type of maintenance. Please refer
to the original operator's manual on the included CD or online
at www.buehler-technologies.com for maintenance informa-
tion.
Centre connection
"IN/OUT"
ting or model FF- moisture detector.
NOTICE
BX410011 ◦ 01/2021