4.5.6 RADIATOR POWER CALIBRATION

The indication of this selection, allowing to assign the correct power to radiator, is displayed by selecting digit "6" present on display left side
(vertical scale from 1 to 7). The display shows radiator nominal voltage in W.
The correct setting of this value is necessary to display consumption, as indicated in paragraph 4.4.
This setting can be modified through the "+" key to increase and through the "-" key to decrease.
A short press on "OK" will confirm and store the adjustment.
If the value is "0000" (default value) no consumption will be displayed.

4.5.7 CALENDAR FUNCTION

The indication of this selection, allowing to activate or deactivate the calendar and thus to automatically
update the daylight saving time mode, is displayed by selecting digit "7" present on display left side
(vertical scale from 1 to 7).
Function is activated and deactivated by pressing repeatedly key "+".
When the function is active the calendar pictogram is lit on the display.
A short press on "OK" will confirm and store the adjustment
Note: A subsequent pressure of the "Prog" key allows quitting the programming mode and going back to the previous mode.

4.5.8 STARTING PARAMETER RESETTING

This function can be accessed by pressing "mode" and "+" keys at the same time for more than 5 seconds.
This operation is used to re-initialize the following parameters to their default values:
- Comfort set-point to 19°C.
- eco reduction to 3.5°C, hence15.5°C.
- freeze protection set-point to 7°C.
- window acknowledgement deactivated.
5.

RADIATOR CLEANING

For your safety, before any cleaning operation, disconnect power supply.
Cleaning operations must be carried out with radiator off and cold.
Do not use abrasive or corrosive products to clean the heating body. Use, for instance, soapy water and then dry the body using a soft cloth.
To clean plastic components, controls and humidifier, use only a dry cloth and avoid contact with chemicals or alcohol.
6.

FAILURES

In case of failure do not use the appliance, disconnect it from power supply and for the repair address only to a technician approved and
authorised to operate on this product.
This appliance is filled with a precise quantity of mineral oil. Reparations that require to open the fluid tank must be carried out by the
manufacturer, its agents or the customer service. The manufacturer shall not be held responsible for damage to people, animals, or property
due to tampering with or improper intervention to the radiator.
EN-31

Publicité

Table des Matières
loading

Table des Matières