SPECIAL FUNCTIONS
Capture Function (HOLD):
The Capture function is used to obtain a single reading and keep it
displayed. This may be useful when the unit may not be visible and grade
information needs to be obtained.
When in the laser beam and power on, momentarily press the Power/Capture switch.
The current elevation reading will be saved. A flashing display will confirm the reading
has been captured. Press any switch to return to normal operation.
When out of the laser beam and power on, momentarily press the Power/Capture
switch. A short intermittent beep and 'WAIT' displayed on the LCD confirm the
Capture mode. (The beeper will turn on to Low if turned off.) Place the receiver in the
beam. The beeper will chirp rapidly after approximately 5 seconds confirming beam
capture. A flashing display will also confirm the reading has been captured. Press any
switch to return to normal operation.
mode is not marked on the unit.
This accuracy is designed to be used when calibrating a laser. It is not recommended
for field use.
Calibration mode will be confirmed on the LCD by the accuracy indicators without
the on-grade bar.
Press any key or cycle power to exit the calibration mode and return to the previously
stored accuracy setting.
Calibration Mode:
Pressing the Power and Accuracy switches together when the unit
is off enables entry into a laser calibration accuracy mode. This
SensoMaster 400
ENGLISH
ENGLISH
31