Commissioning, Operation - Obsolete 54 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Commissioning, operation

GB
6. Commissioning, operation
When screwing the instrument in, the force required to do this must
not be applied through the casing, but only through the spanner flats
provided for this purpose and using a suitable tool.
Installation with
spanner
When using thermowells, they must be filled with a thermal contact
medium in order to reduce the heat transfer resistance between the
outer wall of the sensor and the inner wall of the thermowell. The
working temperature of the thermal compound is -40 ... +200 °C.
10
WARNING!
Before storing the instrument (following operation),
remove any residual media. This is of particular impor-
tance if the medium is hazardous to health, e.g. caustic,
toxic, carcinogenic, radioactive, etc.
The use of liquid damping is always recommended for
temperatures near the dew point (±1 °C around 0 °C).
WARNING!
Do not fill hot thermowells. There is a risk of the oil
spraying out!
WIKA operating instructions model 54, Twin-Temp

Publicité

Table des Matières
loading

Produits Connexes pour Obsolete 54

Table des Matières