Turn on the all-pole circuit breaker located on the power sup-
ply line (see the chapter on connections and electrical safety).
Notes:
- When first turned on, all of the numbers and LEDs on the control
panel will turn on; the codes relative to the software, firmware and
set control model with dip-switch will appear.
When this time has passed, the system will enter stand-by mode.
Press the TEST button of the differential switch located up-
stream from the electrical system to which the spa is connected.
If it does not trip, it may be faulty or it may have tripped due to
problems in the electrical system of the building.
Disconnect the spa and do not use it until you have identi-
fied and eliminated the defect.
Check the operation of the hydromassage pumps using the
key (upon pressing the key for the first time, the pump is acti-
vated; it is turned off by pressing the key a second time).
Check that the spotlights switch on and off using the key
Check that there are no leaks from the hydraulic connections
or other problems.
Completely disinfect the spa by carrying out "super-chlorin-
ation" treatment.
Please refer to the Jacuzzi system water treatment guide
and relative catalogue for details on water quality mainte-
nance, the methods and warnings governing the use of rela-
tive chemical products.
After a few hours, turn off the omnipolar switch.
Open the drain valve(s) and completely empty the spa.
If included, re-install the front and side panels.
CAUTION
Do not use the spa the first time you start it as there is a
high concentration of chlorine in the water during this
phase. Immediately empty the bath.
Contact the local authorities for the standards govern-
ing the discharge of chemically treated water.
Close the drain valve(s) and fill the spa again with fresh water
as previously explained.
Turn the omnipolar switch back on and check that the spa
works correctly.
Check and as necessary modify the water filtering cycles
based on how you intend to use the spa.
Installation of front and side panels
(where included)
Consult the drawings and information relevant to the supplied model.
(
2, part.1) Insert the rubber spacers on the threaded pins
(located on the lower part of the support legs).
Wood panels (--> Sasha mi) can ONLY be used for inte-
rior installations.
(
2, part.2) Set one of the two panels with corners (A-B) at
the edge of the tub and check that the slots on the lower bracket
coincide with the threaded pins.
(
2, part.3-4) Insert the edge of the upper bracket in the
under-edge profile. Then set the panel next to the tub, so that
the threaded pins are inserted into the slots. (part.5)Temporarily
fasten the panel with the indicated nuts.
.
Install the other panel in the same way.
Using the same procedure, install the front panels (C and D). To
make insertion easier, if necessary pull out on panels A and B.
Finally, make sure the panels are aligned with one another.
Permanently secure the panels by tightening the nuts all the
way, until any vertical gaps are closed between the panel and
the corner.

Control panel and functions

CAUTION
Only modify the parameters indicated: do not change the
configuration of the other parameters.
(
5) All spa functions are managed by the control panel on the
tub, as are the respective settings/programming.
NOTE: the display is equipped with keys "
or decrease the values.

Setting the water temperature

The water is heated by a tubular electrical heater. Do not set an
excessively high water temperature, i.e. over the limit of 40 °C. The
recommended temperature is 35-36 °C.
NOTE: with the version with 1.5 Kw heater, when the pump is
activated, the heater is turned off (the LED relative to the symbol
flashes) and is turned on once again after the pump has been
switched off.

Water heating temperature ("set point").

To check or modify the water heating temperature, do the following:
Press keys "
" or "
memorized temperature.
25
25
" and "
" to increase
": the display will show the current

Publicité