External Triggering Of An Additional Lubrication Cycle; Fault Indication; To Remedy A Fault - Lincoln Quicklub 236-13891-1 Instructions De Service

Plaquette de circuits imprimés pour pompe 203
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

User Manual
Operating Instructions

External triggering of an additional lubrication cycle

PCB 9
Pushbutton for external triggering of an additional lubrication
cycle

Fault indication

The signal output takes place with the right-side LED (pos. 3)
4 times flashing signal
System
Fault:
Signal output
Change to the factory set-
ting if signal is ignored

To remedy a fault

IMPORTANT
The pump must be checked by triggering an
additional lubrication cycle.
6001a 02
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
20 002458
Rotary switch (pos. 2 or 4)
LED, right-side (pos. 3)
Rotary switc h on switching posi-
tion 0
4 times flashing signal, motor runs
along with flashing frequency
Pr ess pushbutton > 2 seconds.
1)
and is implemented as follows:
3 times flashing signal
System
Fault:
Signal output
1)
see fig. PCB 8
In the case of a fault, check whether the centralized lubri-
cation pump and the connected system are malfunctioning.
Eliminate the cause of the fault (s ee chapter "Trouble-
shooting").
2.6EN-28006-A09
Pushbutton (pos. 5)
LED, right-side (pos. 3)
Short-circuit at the pushbutton or at
the connection to the external illu-
minated pushbutton.
3 times flashing signal, motor runs
along with flashing frequency
Page 7 of 20