Operating Instructions
PCB 7
Rotary switch for lubricating time, red
Switch position
1
Seconds
8
Minutes
2
Operational Test / To Trigger an Additional Lubrication Cycle
PCB 8
Components of the control p.c.b.
1
- LED, left-side
2
- Rotary switch to set pause time
3
- LED, right-side
4
- Rotary switch to set lubricating time
5
- Pushbutton to trigger additional lubrication cycle
Page 6 of 20
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
T -PCBv-0 20e08
2
3
4
5
16
24
32
40
4
6
8
10
T-PCBv-020f08

Lubricating time setting

The lubric ating tim e can be set to 15 different settings by
mans of the red rotary switch.
Depending on the position of the jumper (see fig. PCB 5
the necess ary tim e interval is adjustable (8-120 seconds or
2-30 minutes).
NOTE
During switching position 0 a failure report
at the light emitting diode takes place on the
right LED 3 (see fig. PCB 8).
At the same time the factory-set lubricating
6001a02
time is accepted.
6
7
8
9
48
56
64
72
12
14
16
18
Switch on the power supply (machine contact / driving
switch).
To check whether power is applied to the printed circuit
board, obs erve whether the LED 1 is lit.
To check the pum p operation it is possible to perform an

operational test.

Pr ess illum inated pushbutton 5 on p.c.b. > 2 sec. until the
right-side LED 3 is lit.
Then the pause time lapses shorter and is followed by a
normal lubrication cycle.
Additional lubrication cycles are possible at any time by
triggering the illuminated pushbutton.