h ousing
Mode of Operation
PCB 2
Printed circuit board 236-13891-1
>
Pause tim e
PCB 3
Time sequence diagram
1)
Operating cycle = Pause time + Lubricating time
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
20002 443b-1
Operating
<
1)
Cycle
>
<
The print ed circuit board 1 (for VDC & VAC pumps) and
the power supply board 2 (only for VAC pumps) are in-
tegrated in the pump housing.
6001a02
1
- control printed circuit board
2
- power supply board
6 344b04
The printed circuit board automatically controls the se-
quence of the pause and lubricating times of the
lubrication
pump.
The sequence of the pause and lubricating times is acti-
vated when the power supply is switched on:
- via machine contact ... ............. for VDC or VAC pumps
............................................... industrial application
- via driving switch ........................ only for VDC pumps
.................................................. mobile applicaiton
A lubrication cycle consis ts of one pause time and one
lubricating time. Once the pause time has elapsed, the lu-
bricating time starts to run. This operating cycle is repeated
permanently after the machine has been put into operation.
During the lubricating time, the pump element dispenses
the lubricant to the lubrication points via progressive me-
tering devices.
2.6EN-28006-A09
IM PORTANT
Whenever the pum p housing has been
opened (e. g. for replacing of the p.c.b.), the
housing cover (including the foamed seal)
must be replaced.