Electrical Connection; Electrical Data - Viva VVA62E150 Notice D'utilisation Et De Montage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the mains lead are coloured in
accordance with the following code:
Green and Yellow
– Earth
Blue
– Neutral
Brown
– Live
If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.
This is what you have to do:
1. Connect the green and yellow (Earth)
wire to the terminal in the plug marked
'E' or with the symbol (
coloured green or green and yellow.
2. Connect the blue (Neutral) wire to the
terminal in the plug marked 'N' or
coloured black.
3. Connect the brown (Live) wire to the
terminal marked 'L', or coloured red.
The extractor hood should only be con-
nected to an earthed socket that has been
installed according to relevant
regulations.
If possible, site the earthed socket directly
behind the chimney panelling.
K The earthed socket should be
connected via its own circuit.
K If the earthed socket is no longer
accessible following installation of the
extractor hood, ensure that there is a
permanently installed disconnector.
If it is necessary to wire the extractor
hood directly into the mains:
The extractor hood should only be
connected to the electricity supply by a
properly qualified electrician.
A separator must be installed in the
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such
devices include circuit breakers and con-
tactors.
If the connecting cable for this
appliance is damaged, the cable must be
replaced by the manufacturer or his
customer service or a similarly qualified
person in order to prevent serious injury to
the user.

Electrical data:

Are to be found on the name plate inside
the appliance after removal of the filter
frame.
Before undertaking any repairs,
always disconnect the extractor hood from
the electricity supply.
Length of the connecting cable: 1.30 m.
This extractor hood corresponds to EC
regulations concerning RF interference
suppression.
Installation
This extractor hood is intended to be
mounted onto the kitchen wall.
1. Remove the grease filter (refer to
Operating Instructions).
2. Draw a line on the wall from the ceiling
to the lower edge of the hood at the
centre of the location where the hood is
going to be mounted.
3. Using the template, mark positions on
the wall for the screws.
Ensure that the minimum distance bet-
ween the hob and the extractor hood is
maintained – 550 mm for an electric hob
and 650 mm for a gas hob. The bottom
), or
edge of the template equates to the lower
edge of the extractor hood.
4. Drill 5 holes (dia. 8 mm) for the
extractor hood and 4 holes (dia. 8 mm)
for the brackets for fixing the flue ducts
and insert wall plugs flush with the wall.
27
68
465
113
39
mind.
550 Elektro
650 Gas
228
Note: Take into account any special
accessories that are going to be fitted.
5. Screw on the 2 brackets for fixing the
upper and lower flue ducts.
6. In order to help fix the hood onto the
wall, screw in the middle screw (without
a washer) until it protrudes by approx.
5 mm.
7. Hook the extractor hood over the screw
in the wall
ca. 5mm