FT 90
Fig.2 : Minimum position
Fig.3 : Medium position
Fig.4 : Maximum position
Open the valve on the gas cylinder.
Put the control knob in start position
(Fig.1) and press down.
Only this action allows gas to flow to the
pilot and middle ceramic burner.
After 10 seconds - while holding the
control knob in pressed condition - push
the piezoelectric igniting button fully
down. It could be necessary to push the
piezo button several times before the
pilot light. Each time you push the piezo
button down, you will hear a clicking
sound as well as see a spark on the pilot
burner. This spark would light the pilot.
Once the pilot is lit, continue on holding
the gas control knob in the pressed
position for further 20 seconds to wait for
the flame safety device to act and keep
the burning go on. Warning: Do not hold
the control knob pressed down for over
more than 40 seconds.
Release the control knob from its pressed
condition and put it in the desired heating
position: Fig.2 = minimum, Fig.3 =
medium, Fig.4 = maximum.
www.toolland.eu
When you want to turn off the gas heater,
you should turn the control knob to the
minimum position (Fig.2) and close firmly
the gas supply.
WARNING! You MUST close the gas
supply for shutting down the
appliance. If the gas supply is not
closed the appliance will not be shut
down.
After lighting, the heater will operate with
minimum power. If you would like to use
this heating power further you need to
turn the control knob from start position
(Fig.1) to minimum position (Fig.2). This
is important for a proper operation of
your appliance.
Do you have questions about this appliance?
Do not hesitate to contact our technical
service. On the website www.toolland.be you
will find more information.
6. MAINTENANCE
Always turn off the appliance before
cleaning it and wait till it is cooled
completely.
To clean the outside of the heater, use a
soft cloth soaked with water and a liquid
detergent. Do not use scouring pads or
abrasive products. Do not use water or
abrasive products.
Regularly inspect the atmosphere
analyzer and the aeration holes.
Regularly check the condition of the
connections. Check the condition of the
hose and the pressure regulator every
time the gas cylinder is changed.
Take care not to hit or damage the
surface of the burner, the fittings and gas
tubes, the tap and all the other
components of the gas circuit.
We recommend that you have the heater
inspected once a year by a qualified
professional.
If you decide not to use the heater for an
extended period, you must follow the
instructions bellow:
-
Close the tap on the cylinder and
disconnect the pressure regulator
from the cylinder.
-
Store the cylinder in a well-ventilated
room, far from inflammable or
English
20