Operating instructions SATA filter 400
tion [A]/[B]
3. Complete SATA filter 464 by glueing in the threaded connection piece
[E] the insert [F] and the sleeve nut [G]
4. Screw on [2-2] SATA filter 464 [C]
5. Screw on [2-3] air outlet module [D]
8.
Use
Use solvent-resistant, antistatic, undamaged, technically flawless com-
pressed air hoses with a continuous pressure resistance of minimum 10
bar, e.g. Art. No. 53090!
Notice!
• Mount compressed air connector ¼" (internal thread) or matching
SATA-quick-action coupling G ¼" (internal thread) (item no. 13599,
not included in delivery) on the ball tap [1-6].
• For regular filter maintenance, replace and activate the SATA filter
timer of the respective filter stage (sintered filters and fine filters every
6 months, activated carbon filters every 3 months).
6. Connect suitable compressed air hose.
7. Turn the pressure adjustment knob [1-5] in counterclockwise direction
to the maximum; state = closed
8. Fully open ball valve [1-6]
9. Turn pressure adjustment knob [1-5] to the right until required pres-
sure is displayed on the pressure gauge [1-3].
10. Control pressure when operating the spray gun (trigger fully pulled)
and re-adjust, if necessary.
9.
Function
9.1. Filter stage [A]:
The first filtering stage separates particles > 5 µ as well as condensed
water and oil. A sinter filter (Art. No. 22160) is integrated in the filter.
Notice!
Sintered filter:
Warning! Attention!
EN
75