Fault
Displays
do not illuminate.
The temperature in
the freezer
compartment is too
warm.
Freezer compartment
door was open
for a long time;
temperature is no
longer reached.
46
Possible cause
Power failure; the fuse
has been switched off;
the mains plug
has not been inserted
properly.
Appliance opened
frequently.
The ventilation
openings have been
covered.
Large quantities of
fresh food are being
frozen.
The evaporator
(refrigeration
generator)
in the No Frost system
is covered in thick ice
and can no
longer be defrosted
fully automatically.
Remedial action
Connect mains plug. Check whether
the power is on, check the fuses.
Do not open the appliance
unnecessarily.
Remove obstacles.
Do not exceed max. freezing
capacity.
To defrost the evaporator, remove
the frozen food
with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move
it away from the wall. Leave
the appliance door open.
After approx. 20 min.
the condensation begins to run
into the evaporation pan,
at the rear of the appliance. Fig. *
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation
with a sponge.
The evaporator is defrosted when
the water stops running
into the evaporation pan. Clean
the interior. Switch the appliance
back on again.