CAUTION: OVERLOAD:
If you use extension leads, these should have a cable
cross-section of at least 1.5 mm
Do not use any multiple sockets, as this device is too
powerful.

Using the Device

CAUTION:
Before you begin cleaning you should test the materials to
be cleaned as to their suitability for cleaning with steam. Do
not hold the steam nozzle for too long and too close in one
position.
After you have fi lled the kettle with water and selected a cleaning
attachment, please proceed as follows:
1. Turn the lock (22) on the steam pistol (20) to OFF/LOCK
without the steam switch (21) pressed in (Fig. A).
2. Connect the device to a duly installed 230 V/50 Hz protec-
tive contact socket.
3. Press the on/off switch (4) (Fig. F). The red control lamp (3)
lights up. The temperature control lamp (2) shows that the
device is heating up.
4. After approx. 12 min the steam temperature has been
reached and the temperature control lamp (2) goes off.
The device is ready for operation. During use this control
lamp shows that the water is being heated up again.
WARNING:
If the steam switch is pressed while the orange lamp is on,
it is possible for hot water to be ejected from the nozzle.
5. For the purposes of cleaning turn the lock (22) on the steam
pistol (20) to ON (Fig. B1).
6. Point the steam nozzle at the surface to be cleaned and
press the steam switch (21) (Fig. B2).
7. Use the lock (22) to turn the steam pistol to permanent
steam. Keep the steam switch pressed down and turn the
lock to OFF/LOCK at the same time (Fig. C3).
8. In order to release the lock again, please proceed as
follows: hold down the steam switch and turn the lock to ON
at the same time (Fig. D4).
NOTE:
During operation please ensure that the hose does not
become twisted or squashed.
Filling up the Water Boiler when using the Device
If there is no more water in the vessel no steam is emitted when
the steam switch (21) is pressed. The water has to be fi lled up
as follows:
1. Press the on/off switch (4). The red control lamp goes off.
2. Remove the mains plug from the socket!
3. Release the residual pressure with the steam switch (21)
(see "Initial Operation", points 2 and 3).
05_DR 3280.indd 31
05_DR 3280.indd 31
2
.
4. Slowly open the safety lock (6) and wait a few seconds
5. Fill freshwater from the measuring beaker (15) into the
6. Fasten the safety lock again.
7. Reinsert the plug into the socket and switch on the device
When you have fi nished using the device
1. Press the on/off switch (4). The red control lamp goes off.
2. Remove the mains plug from the socket!
3. Release the residual pressure with the steam switch (21)
4. Allow the device to cool down for approx. 1 hour before you
WARNING: Danger of Injury!
Please open the safety lock (6) only when no more
steam comes out of the nozzle.
before opening it completely until the overpressure has been
released.
NOTE:
For your protection the safety lock has a release device.
If the pressure in the kettle is still too high, this release
device prevents it from being opened.
kettle. Take care of water splashes that might come out of
the boiler. In order to avoid water spray, please use the fun-
nel supplied (Fig. E). Fill the water in slowly. Do not overfi ll!
Max. water capacity: 1.5 litres
using the on/off switch.
(see "Initial Operation", points 2 and 3).
put it away.

Cleaning and Maintenance

WARNING:
Always remove the mains plug before cleaning the device.
Under no circumstances should you immerse the device
in water for cleaning purposes. Otherwise this might result
in an electric shock or fi re.
CAUTION:
Do not use a wire brush or any abrasive items.
Do not use any acidic or abrasive detergents.
Before the device is put away or cleaned it must have com-
pletely cooled down.
The device and accessories should only be cleaned with a
slightly damp cloth.
In order to ensure that the device will function correctly
for a long time, approximately 15 litres of water should be
passed through it in order to rinse out lime residues from the
boiler. You should only use clean water for this. Max. water
capacity: 1.5 litres.