5. Clean the well enclosure thoroughly in preparation for
initial operation. Refer to the MAINTENANCE section for
proper cleaning procedures.
NOTE: If a catch pan is used underneath the drain fitting, make
sure the pan is emptied regularly to prevent over-flowing.
6. Plug the unit into a properly grounded electrical receptacle
of the correct voltage, size, and plug configuration. See
the SPECIFICATIONS section for details.
Installing the Control Panel Remotely
Use the following procedure to install the control panel remotely.
WARNING
Control panel must be mounted in a vertical surface.
Mounting control panel in a horizontal surface may result
in the collection of liquids and lead to electric shock.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the "Control Panel Cutout and Screw Hole
Dimensions" chart for the cutout dimensions.
2. Remove the four trim cover screws from the control panel
and remove the trim cover.
3. Position the control panel into the cutout opening through
the backside.
4. Fasten the control panel to the vertical surface using four
screws (not supplied).

Countertop Cutout Dimensions

Width
Model
(A)
17-1/8"–18"
CWB-1
(435–457 mm)
30-1/8"–31"
CWB-2
(765–787 mm)
43-1/8"–44"
CWB-3
(1096–1118 mm)
Form No. CWBM-0717
NOTE: Make sure the width of the control panel cutout does
Depth
(B)
25-3/16"–26"
(640–660 mm)
25-3/16"–26"
(640–660 mm)
25-3/16"–26"
(640–660 mm)
CWB-6
A
CWB Series Countertop Cutout Dimensions
9
5. Apply a 1/4" (6 mm) bead of NSF-approved silicone sealant
where the trim cover will contact the cabinet surface. Refer
to the "Control Panel Cutout and Screw Hole Dimensions"
illustration for more information.
6. Reinstall the trim cover on the control panel and secure
in position using the four trim cover screws. Make sure to
embed the trim cover edge into the silicone.
Silicone Sealant
7/16"
(11 mm)
3/8"
(9 mm)
7-7/16"
(189 mm)
7-3/4"
(196 mm)
Control Panel Cutout and Screw Hole Dimensions
not exceed the above dimension.
Width
Model
(A)
56-1/8"–57"
CWB-4
(1426–1448 mm)
69-1/8"–70"
CWB-5
(1756–1778 mm)
82-1/8"–83"
CWB-6
(2086–2108 mm)
INSTALLATION
1-1/16"
(27 mm)
5-5/8"
(143 mm)
3-1/2"
(89 mm)
Depth
(B)
25-3/16"–26"
(640–660 mm)
25-3/16"–26"
(640–660 mm)