INSTALLATION
Specifi cation
A1
Electronic assembly (control unit)
A2
Electronic assembly (programming unit)
C1
Capacitor
E1
Heating element (1.5 kW)
F1
High limit safety cut-out TSR (189 °F ±8 / 87 °C ±5 )
F2
Motor overload relay M1
F3
High pressure switch (348 psi / 24 bar)
F4
Fuse
G1
Impressed current anode
M1
Compressor
Material losses
!
If X0/2 is connected, the power supply to the appliance
must be a permanent connection (See 11.4.3, "Connec-
tion with external signal transmitter", pg. 24). Never
interchange L1 and N.
16.3 Data table
Hydraulic data
Nominal capacity
Application limits
Maximum DHW temperature
Heat source min./max. application limits
Min. clearance in front of air intake & air discharge grill
Minimum clearance above the appliance
Min. installation room floor area
Min. installation room volume
Max. permissible operating pressure, cold water/DHW
Output details to EN 16147
Nominal DHW temperature
Maximum available amount of DHW at 104 °F/40 °C
Heat-up time (59 °F ambient air temperature)
Heat-up time (44 °F ambient air temperature)
Power consumption, standby period (EN 16147 / A15)
Power consumption, standby period (EN 16147 / A7)
COP (EN 16147 / A15)
COP (EN 16147 / A7)
Heating output
Average heating output (EN 16147 / A15)
Average heating output (EN 16147 / A7)
Power consumption
Average heat pump power consumption with 59 °F / 15 °C air
Average heat pump power consumption with 44 °F / 7 °C air
Max. heat pump power consumption (excl. start-up)
Power consumption, booster element
Max. power consumption heat pump + booster element
Energy Star
Energy Factor
First hour rating
DOE estimated annual energy usage
Electrical data
Power connection
Max. operating current
Max. starting current
Required circuit breaker
Sound data *
Sound power level (EN 12102)
Sound pressure level at 3.3 ft (1 m)
www.stiebel-eltron-usa.com
M2
Fan
N1
Thermostat TSR (149 °F ±8 / 65 °C ±5)
R1
Resistor 380 Ohm
S1
DIP-switch (operating mode)
S2
DIP-switch
T1
Temperature sensor (dome/integral)
T4
Temperature sensor (evaporator
X0
Mains terminal
X1
Internal terminals
X3
Terminal
Note
Never wire up terminal X0/1.
Accelera® 220 E
233058
58 gal / 220 l
149 °F / 65 °C
42–108 °F / 6–42 °C
15 ¾ in / 400 mm
13 ¾ in / 350 mm
2
64.6 ft² / 6 m
3
800 ft³ / 22.7 m
116 PSI / 0.8 MPa
131–149 °F / 55–65 °C
96 gal / 365 l
6.98–8.70 hr
10.02–11.97 hr
112–212 BTU/hr / 0.033-0.062 kW
157–256 BTU/hr / 0.045-0.075 kW
3.22-2.95
2.61-2.22
5735-5530 BTU/hr / 1.68-1.62 kW
4200-3995 BTU/hr / 1.23-1.17 kW
1773–1875 BTU/hr / 0.52–0.55 kW
1600–1807 BTU/hr / 0.47–0.53 kW
2216 BTU/hr / 0.65 kW
5115 BTU/hr / 1.50 kW
7331 BTU/hr / 2.15 kW
3.05
50.3 gal / 190.4 l
1406 kWh/year
L1,L2,G/220-240 V/60/50 Hz
8.54 A
23.44 A
15 A, Type C
60 dB(A)
52 dB(A)
Accelera® 300 E
233059
79.8 gal / 302 l
149 °F / 65 °C
42–108 °F / 6–42 °C
15 ¾ in / 400 mm
13 ¾ in / 350 mm
2
64.6 ft² / 6 m
3
800 ft³ / 22.7 m
116 PSI / 0.8 MPa
131 °F / 55 °C
106.7 gal / 404 l
9.75 hr
13.41 hr
153 BTU/hr / 0.045 kW
215 BTU/hr /0.063 kW
3.27
2.65
5767 BTU/hr / 1.69 kW
4200 BTU/hr / 1.23 kW
1773 BTU/hr / 0.52 kW
1600 BTU/hr / 0.47 kW
2216 BTU/hr / 0.65 kW
5115 BTU/hr / 1.50 kW
7331 BTU/hr / 2.15 kW
3.39
75.1 gal / 190.4 l
1289 kWh/year
L1,L2,G/220-240 V/60/50 Hz
8.54 A
23.44 A
15 A, Type C
60 dB(A)
52 dB(A)