Connection of the hob
Setting up the configurations:
For the various kinds of connection, use the
brass bridges which are in the box next to the
terminal
Monophase 230V~1P+N
(not for the Netherlands!)
Put the 1st bridge between terminal 1 and 2,
the 2nd between 3 and 4.
Attach the earth to the terminate "earth", the
neutral N to terminal 3 (or 4), the Phase L to
one of the terminals 1 or 2.
Biphase 400V~2P+N
Put a bridge between terminal 3 and 4.
Attach the earth to the terminate "earth", the
neutral N to terminal 3 (or 4), the Phase L1
to the terminals 1 and the Phase L2 to the
terminal 2.
Boretti cannot be held responsible for any incident resulting from incorrect connection
or which could arise from the use of an appliance which has not been earthed
72
or has been equipped with a faulty earth connection.
Biphase 230V~2P+2N
Attach L1 to terminal 1, L2 to terminal 2, N1
to terminal 3, N2 to terminal 4 and earth to
terminal "earth"
Caution! Ensure that you correctly attach the
wires and the bridges. Tighten the screws
properly. Before making the connection, we
strongly advise you to locate the phase(s), neu-
tral and earth on the mains. Note: the bridges
between terminals 4-5 and between terminals
1-2 were installed during the factory check.