Cleaning and Maintenance

Filter Replacement

The Filters may accumulate minerals and other impurities that occur
naturally in any water supply. While your Humidifier came equipped
with two Filters, you will eventually have to replace them.
EVAP1 EVAP3 MAINT
EVAP1 EVAP3 MAINT
Get the free mobile app at
Get the free mobile app for your phone
http:/ / gettag.mobi
View filter
http:/ / gettag.mobi
replacement tutorial on
your mobile device.
When to Replace: Many factors affect the frequency in which
the Filters will need to be replaced - including amount of use,
water hardness, and outside environmental factors. For heavy
use, using the unit continuously, we recommend replacing the
Filters approximately once a month. For lighter use, using the
unit intermittently, we recommend replacing the Filters every two
months.
The Filters will need to be replaced earlier if the Filters become
hard or are no longer absorbing the water effectively. Replace
Filters with only genuine Vornado® brand Filters. While other
brands may fit our units, these Filters do not carry the same quality
and life as our own and can diminish the Humidifier's performance.
10 English
How to Replace:
1.
Turn the unit off and unplug. Remove Power Head (A).
A
2.
Remove and discard used Filters (B).
B
3.
Install new genuine Vornado Filters by making sure they are flush
against the sides of the unit and touching the bottom of the Base.
4.
Replace Power Head. Your Humidifier is now ready for use.

Cleaning Instructions

Proper cleaning of your Evaporative Vortex Humidifier is essential
to the air quality and performance of your unit. The frequency in
which your Humidifier will need to be cleaned will vary, depending
on use, water hardness, and outside environmental factors. It is
recommended, assuming average use, to thouroughly clean the unit
several times throughout the season, or when algae, mineral deposits
or other particles begin to form.
To clean:
1.
Turn the Humidifier Off and unplug. Do not submerge in water.
2.
Remove Power Head and Filters (See FILTER REPLACEMENT for
instructions).
3.
Remove Water Tank and Inlet Grill. To remove Inlet Grill, undo the
latch (A) and lift (B).
A
B
4.
Empty water from Base and Water Tank. (See FILLING WATER
TANK for instructions).
Note: Do not operate the unit during cleaning.
5.
Fill Base and Water Tank with a mixture of water and white vinegar
- mixed at a ratio of one (1) 8 oz. cup of undiluted white vinegar
per 1 gallon of water (C). Do not overfill, discard unused portion.
Solution should remain in Base and Water Tank for 20 minutes to
dissolve any residue.
Cleaning and Maintenance
C
+
8 oz.
White Vinegar
6.
Empty after 20 minutes and clean all interior surfaces of Base and
Water Tank with soft brush. Dampen soft cloth with undiluted white
vinegar and wipe down to remove scale.
7.
Rinse thoroughly with clean warm water before disinfecting.
To Disinfect:
1.
Fill Base and Water Tank with a mixture of water and chlorine
bleach - mixed at a ratio of one (1) teaspoon of chlorine bleach
per 1 gallon of water (D). Do not overfill, discard unused portion.
Solution should remain in Base and Water Tank for 20 minutes to
fully disinfect.
D
+
1 tsp.
Chlorine Bleach
2.
Rinse with water until bleach smell is gone. Dry with clean cloth or
paper towel.
3.
Reinstall all components. Components must be securely in place for
unit to function properly.
1 gal.