ERROR MESSAGES

The Power Peak ® B6 EQ-BID is equipped with special safety features to ensure safe and
reliable charging and discharging operation. As soon as a fault occurs, a corresponding
message appears in the display and the piezo buzzer emits a shrill warning tone. After
eliminating the cause, the following error messages can be acknowledged by pressing
g
g
g
Operating Instructions
Power Peak ® B6 EQ-BID
,
,
g
g
g
g
any button.
Input voltage outside permitted range (11 - 15 Volt)
Charging or discharging started without connection
to battery, make connection
Battery connected with polarity reversed, check con-
nection
Break in charging/discharging current circuit, check
connection
Short-circuit in charging/discharging current circuit,
check connections
Battery/output voltage too high, check number of
cells
Battery/output voltage too low, check number of
cells
BID chip/key separated from charger during active
operation, stop procedure, check connection to chip
and restart
Voltage level of connected cell(s) above 4.3 Volt
Voltage level of connected cell(s) below 2.75 Volt for
LiPo and LiIo or 2.0 Volt for LiFe
Voltage sensor lead not connected
Temperature sensor not connected correctly or tem-
perature above 100°C
Temperature below 0°C