Warnings For Installation And; Warnings For Assembly And; Troubleshooting - Waterco Supastream 2HP Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNINGS FOR INSTALLATION AND ASSEMBLY TASKS
1. When connecting electric cables to the motor of the pump, be careful to correctly arrange them
inside the connection box, verify that no bits of cable are left inside the box on closing it. See that
the earth wire is correctly connected. When connecting the motor, follow the wiring diagram
supplied with the pump.
2. Be especially careful that no water enters the motor or electrical parts under voltage.
3. In the event that the planned use is not as specified, adaptations and supplementary technical
rules may be necessary.
• WARNINGS FOR START UP
Before starting the pump, verify the calibration of the electrical protection devices of the motor and
that the protections against electrical and mechanical contacts are correctly positioned and attached.
WARNINGS FOR ASSEMBLY AND MAINTENANCE TASKS
1. Be especially careful that no water enters the motor or the electrical parts under voltage.
2. Avoid all contact, even accidental, with the moving parts of the pump.
3. Wait until the pump has stopped completely before handling it in any way.
4. Before carrying out electrical or mechanical maintenance tasks, make sure that the machine
has been disconnected from the mains and that starting devices have been locked.
5. It is advisable to follow the steps listed below before handling the pump in any way.
a) Turn off the voltage to the pump.
b) Lock starting devices.
c) Verify that there is no voltage in the circuits, including ancillary devices and auxiliary circuits.
d) Wait until motor stops completely.
The above list should be considered indicative and not binding for the purpose of safety;
specific safety rules may exist in particular regulations.
Regularly verify:
1. The correct attachments of the mechanical parts and of the support screws of the pump.
2. The correct position, attachment and condition of the supply cables and of the insulating parts.
3. The temperature of the motor. In the event of any irregularity stop the machine immediately and
have it repaired.
4. The vibration of the pump. In the case of any irregularity, stop the machine immediately and have
it repaired.
Owing to the complexity of the cases covered, the instructions for installation, use and maintenance
contained in this manual do not attempt to examine all possible and imaginable cases of service and
maintenance. If supplementary instructions are required or if special problems arise, do not hesitate
to contact the distributor or to address directly the manufacturer of the pump.
TROUBLE SHOOTING
SYMPTOMS
PROBABLE CAUSE
1. PUMP WILL
Suction air leak
NOT PRIME
No water in the pump
Closed valves or blocked lines
2. MOTOR WILL
No power to motor
NOT RUN
Pump jammed
3. LOW FLOW
Dirty filter
Dirty Skimmer and Pump strainer
Suction air leak
Closed valve or blocked line
4. MOTOR RUNS
Low or incorrect voltage
HOT
Installed in direct sunlight
Poor ventilation
5. NOISY PUMP
Bad bearing
OPERATION
Air leak in suction
Suction blockage
Foreign matter in impeller
Cavitations
6. MOTOR OVER
Motor not connected properly
LOAD CUTS
Low incoming voltage
OUT
Over load due to binding in pump
or wrong size impeller
Warning: If the Waterco Limited pump is within the stated warranty period and you experience
faults always contact your supplier or the nearest Waterco Limited branch for advice. Failure to
do this may void warranty. Refer to warranty documentation supplied with pump.
All electrical work is to be carried out by a Qualified Electrician; under no circumstances should
you attempt repairs on the electrical components of Waterco Limited pumps unless you are
qualified to do so.
Waterco Pumps
ACTION
Make sure water level is correct through suction points.
Ensure baskets and strainers are free of debris. Tighten
all fittings / unions on the suction side of the pump,
remove and replace mechanical seal.
Make sure hair and lint pot is full.
Open all valves in system, clean skimmer and pump
basket, check pump impeller of blockage.
Check that all electrical switches are on. Ensure the circuit
breakers are properly set. Check if timer is set properly.
Check motor wiring at terminals.
With power switched off turn pump shaft (should spn
freely). If not contact electrician or nearest Waterco
Limited branch for service.
Backwash or clean cartridge.
Clean skimmer and pump strainer.
See 1.
See 1.
Supply to be corrected by Electrician.
Motors run hot to touch and is normal. Thermal overload
protector will function to turn them off if there is an
overload or high temperature problem.
Shield from the weather.
Do not tightly cover or enclose motor.
Have electrian replace.
See 1.
Locate and clear blockage.
Dismantle pump and remove foreign matter and debris
from around impeller.
Improve suction, reduce suction lift, reduce number of
fittings, increase pipe size, increase discharge pressure
and reduce flow by throttling discharge valve.
Have electrician check wiring.
Have electrician check voltage, ensure pump is not
running on an extension cord. Report low supply to
authorities.
Contact Waterco Limited for service.
I pg 07