MAINTENANCE
The strainer basket in the hair and lint pot bowl should be inspected and cleaned at regular intervals.
1. Remove lid and lift out basket.
2. Remove debris and hose off with clean water if necessary.
3. Inspect the lid gasket, lubricate with SILICON based grease only if needed.
If it is damaged replace.
4. Replace the strainer.
5. Re-prime the hair and lint pot bowl.
6. Correctly locate the o-ring.
7. Replace the lid (hand tighten) only.
8. Switch on pump.
In Climates where the pump may be exposed to frost or freezing, care must be taken to ensure the
pump is protected from damage.
It is recommended that if the pump is not used during this winter period it should be drained
completely.
Waterco Limited supply drain plugs for this purpose.
Do not replace the drain plug. Store it in a safe place until you require the use of the pump.
An example would be within the hair and lint pot bowl basket.
If at all possible remove the pump away and store it in a dry location during this period.
When you re activate the pump ensure all seals and o-rings are in operational condition, re-grease if
necessary (replace) if unsure of condition.
• Check that the motor shaft moves freely before re-activation.
FLUID TEMPERATURE
The permissible temperature is > than 0˚C and < than 35˚C. The pump should never be operated
outside of these temperatures or damage may occur.
SERVICING
If the need arises or you are unable to service your Waterco Limited pump always contact your
authorized Waterco Limited Service agent for advise or infield service.
• Always use genuine Waterco Limited replacement parts when carrying out pump maintenance.
GENERAL SAFETY RULES
1. The machines mentioned in the manual are specially designed for the pre-filtering and re-circulation
of water in swimming pools.
2. They are designed to work with clean water at a temperature not exceeding 35 degrees Celsius
(95 degrees Fahrenheit).
3. The installation should be carried out in accordance to the safety instructions of swimming pools,
especially Standard HD 384.7.702, and the specific instructions for each facility.
4. The rules enforce on accident prevention should be carefully followed.
5. Any modification of the pump requires the prior consent of the manufacturer. Original replacement
parts and accessories authorized by the manufacturer ensure a high level of safety. The
manufacturer of the pump assumes no liability for the damage and injuries caused by un-
authorized replacement parts and accessories.
6. During operation, some parts of the pump are subject to dangerous electric voltage. Work may
only be performed on each pump or on the equipment connected to it after disconnecting them
from the mains power, and after disconnecting the starting device.
7. The user should make sure that assembly and maintenance tasks are carried out by qualified
authorized persons and that these persons have first carefully read the instructions for service
and installation.
8. The operating safety of the pump is only guaranteed if the installation and service instructions are
correctly followed.
9. The limit values stated in the. Technical table should not be exceeded under any condition.
10. In the event of defective operation or fault, contact the technical support department of the
manufacturer or its nearest authorized agents.
11. If the supply cord is damaged, it must be replaced by an authorized service agent.
12. This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliancor instruction concerning use of
the appliance.
Waterco Pumps
I pg 05