To change the limit value, select the desired parameter using
the key SELECT PARAMETER
; hold down the key for
a few seconds to enter configuration mode, indicated by a
flashing led next to the highlighted item (symbol).
Use the arrow keys +/- to increase or decrease the limit value.
Wait approximately 10 seconds without pressing any key to
store the new setting.
The limit value establishes the parameter level beyond
which the speed of the device will switch to automatic mode
(SMART).

MANUAL SPEED ADJUSTMENT

To adjust the motor speed, select FAN (3) using the SELECT
PARAMETER key
, then use the arrow keys +/- to incre-
ase or decrease the operating speed.

FAN STAND-BY

With the FAN function in operation, press the SELECT PARA-
METER key
for a few seconds to put the fan in STAND-
BY mode. In this mode (indicated by a FLASHING RED LED
(7) opposite the light scale (4), the fan motor stays switched
on but without turning. To exit STAND-BY mode, press the
SELECT PARAMETER key
.