Product description

-
Emission EN 61326: 1997 (Klasse A)
-
Susceptibility EN 61326: 1997/A1:1998
LVD: EN 61010-1: 1993
l

2.6 Safety instructions for Ex areas

Please note the Ex-specific safety information for
installation and operation in Ex areas. These safety
instructions are part of the operating instructions
manual and come with the Ex-approved instru-
ments.

2.7 Environmental instructions

Protection of the environment is one of our most
important duties. That is why we have introduced
an environment management system with the goal
of continuously improving company environmental
protection. The environment management system
is certified according to DIN EN ISO 14001.
Please help us fulfil this obligation by observing the
environmental instructions in this manual:
Chapter "Storage and transport"
l
Chapter "Disposal"
l
3 Product description
3.1 Configuration
Scope of delivery
The scope of delivery encompasses:
VEGATRENN 149A Ex separator
l
Documentation
l
-
this operating instructions manual
-
Ex specific safety instructions and, if
necessary, further certificates.

3.2 Principle of operation

Area of application
VEGATRENN 149A Ex is an [EEx ia] separator
with separate power supply for connection of
4 ... 20 mA/HART sensors in two-wire version. As
corresponding electrical equipment, it ensures a
galvanic separation between sensor circuit and
processing circuit and thus between Ex and non-Ex
area.
14
Functional principle
An integrated transmitter power supply powers the
connected sensor. The clamp voltage from the
sensor (4 ... 20 mA) is transferred linear and
galvanically separated to the output. The HART
communication sockets in the front ensure a
bidirectional transmission of HART signals.
Supply
Weitbereichnetzteil mit 20 ... 250 V AC/DC zum
weltweiten Einsatz.
You can find detailed information on the power
supply in chapter "Technical data" in the "Supple-
ment".
3.3 Operation
There are no adjustment elements on VEGA-
TRENN 149A Ex. A parameter adjustment of the
connected sensors can be carried out via the
HART communication sockets. The adjustment of
the connected sensors is carried out preferrably via
a Windows PC with a parameter adjustment
software such as PACTware™ and respective
DTM.

3.4 Storage and transport

Packaging
Your instrument was protected by packaging
during transport. Its capacity to handle normal
loads during transport is assured by a test
according to DIN EN 24180.
The packaging of standard instruments consists of
environment-friendly, recyclable cardboard. For
special versions, PE foam or PE foil is also used.
Dispose of the packaging material via specialised
recycling companies.
Storage and transport temperature
Storage and transport temperature see "Sup-
l
plement - Technical data - Ambient conditions"
Relative humidity 20 ... 85 %
l
VEGATRENN 149A Ex

Publicité

Table des Matières
loading